22 / 120 EN
Split-type room air conditioner / Installation Manual
C
Before performing electrical work, read these regulations
1. All wiring must comply with local and national electrical codes, and must be installed by
a licensed electrician.
2. All electrical connections must be made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work immediately. Explain
your reasoning to the client, and refuse to install the unit until the safety issue is
properly resolved.
4. Power voltage should be within 90-100% of rated voltage. Insufficient power supply
can cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, install a surge protector and main power switch
with a capacity of 1.5 times the maximum current of the unit.
6. If connecting power to fixed wiring, a switch or circuit breaker that disconnects all
poles and has a contact separation of at least 1/8in (3mm) must be incorporated in the
fixed wiring. The qualified technician must use an approved circuit breaker or switch.
7. Only connect the unit to an individual branch circuit outlet. Do not connect another
appliance to that outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be firmly connected. Loose wiring can cause the terminal to overheat,
resulting in product malfunction and possible fire.
10. Do not let wires touch or rest against refrigerant tubing, the compressor, or any
moving parts within the unit.
11. If the unit has an auxiliary electric heater, it must be installed at least 1 meter (40in)
away from any combustible materials.
A
Warning
Before performing an y electrical or wiring work , turn off
the main power to the system.
Step 6: Connect signal cable
The signal cable enables communication between the indoor and outdoor units. You must first choose
the right cable size before preparing it for connection.
Cable Types
t
Indoor Power Cable (if applicable):
H05VV-F or H05V2V2-F
t
Outdoor Power Cable: H07RN-F
t
Signal Cable: H07RN-F
5
Indoor unit installation