Subject to alterations!
...a product from
BAL2076_central lubrication pump_01
19EN
© BEKA
2019 All rights reserved
capacitive
proximity
switch
max.
level
monitoring
min. level
monitoring
min. level
max. level
base
Technical data of capacitive proximity switch:
Contact function:
PNP NC/NO contact
Operating voltage:
10-60 V/DC
Switching current:
max. 200 mA
View onto plug:
1 = +Ub, 10-60V
2 = 0 V ground
3 = NC or NO
PE = not assigned
3
2
1
PE
white
brown
blue
black
C
2
3
1
+UB
(10-60V)
0 V
PE
*
*
optional
white = NC contact
black = NO contact
Fig. 35:
Fig. 34:
Attention!
5.1.3
FKGGM - EP Pump
Proximity switch - connection cubic plug acc. to DIN 43650 - 90-250 V AC:
View onto plug:
brown 1 = L / 90 - 250 V AC
blue 3 = NO contact
Fig. 36:
5.1.2
FKGGM - EP Pump
Proximity switch - connection cubic plug acc. to DIN 43650 - 10-60 V/DC
The NO / NC function must be selected when ordering.
Connect the level monitoring by means of a suitable cable at the contact box.
Connect this to the level monitoring of the pump and tighten the fsastening screw.
Assemble the high pressure hose away from hot parts (max. 50° C) and avoid chafe marks.
3
2
1
PE
brown
blue
1=L / 90 - 250 V AC
3
from 5 mA to max. 250 mA
35