28
6.5.21 Control output 1 (optional):
op1
Control output 1 is an optional factory fitted,
galvanically isolated solid state switch contact which
can be configured to turn
on
and
off
when the Timer
enters a specified states. When control output 1 is
on
the '1' annunciator on the Timer display is
activated.
The function contains four sub-functions,
EnbL
,
op1 on
,
op1 oFF
and
op1 dELA
. To gain access to the
sub-menu select
op1
in the configuration menu and
press
(
which will show the
EnbL
prompt from
which the other sub-functions can be accessed
using the
&
or
*
button.
Control output 1 may be configured to turn
on
when
the Timer enters a selected Timer state and to turn
off
when the Timer enters another specified Timer
state.
e.g. if
run
is selected in the
op1 on
sub-
function and
done
is selected the
op1 off
function.
Control output 1 will turn
on
when the Timer enters
the
run
state and will stay
on
until the Timer enters
the
done
state.
Alternatively, the control output
phase may be reversed by selecting the
n
states
such as
n re5et
.
If control output 1 is required to be
on
in only one
Timer state, this can be achieved with the following
configuration.
op1 on
state required e.g.
run
op1 off
n state required e.g.
n run
In this example when the Timer enters the
run
state
control output 1 turns
on
. When the Timer moves
from the
run
to any other state, control output 1
turns
off
.
The Timer configuration example in section 7.2 of
this manual illustrates the use of the control outputs.
Further examples can be found in Application Guide
AG374 which is available on the BEKA website.
6.5.22 Control output 1 enable:
EnbL
This function allows control output 1 to be enabled
or disabled without altering any other control output
parameters. To check or change the function select
EnbL
from the control output 1 sub-menu and press
(
to reveal if control output 1 is
on
or
oFF
. The
setting can be changed by pressing the
&
or
*
button followed by the
)
button to return to the
control output 1 sub-menu.
6.5.23 Control output 1
on
at :
op1 on
Control output 1 may be configured to turn
on
when
the Timer enters in any one of the five Timer states.
Alternatively, the control output 1 phase may be
reversed, by selecting an
n
state which will cause
the control output to turn
on
when the Timer enters
any other than the specified Timer state.
Timer
states are shown in Fig 12.
To define when control output 1 turns
on
select
op1 on
from the sub-menu and press
(
to show the
existing setting. Pressing the
&
or
*
button will
scroll through the options:
Display
Control output 1 turns
on
when Timer enters selected state
re5et
Reset state
run
Running state
pau5ed
Paused state
delay
Restart delay state
done
Complete state
Control output 1 turns
on
when Timer enters any other than
the selected state
n re5et
Reset state
n run
Running state
n pau5ed
Paused state
n delay
Restart delay state
n done
Complete
state
When the required setting has been selected press
)
to enter the selection and return to the sub-
menu.
Содержание BA377NE
Страница 1: ...Issue 6 3rd July 2018 BA377NE Rugged one input Ex nA and Ex tc Timer or Clock Issue 6...
Страница 4: ...4...
Страница 24: ...24...
Страница 25: ...25...
Страница 36: ...36...