932 655 638
2014-02-14
|
Beissbarth GmbH
42 | MT 788 | Faults
en
11. Faults
i
Other possible malfunctions are primarily of a technical nature and are to be checked and if necessary rectified
by a qualified engineer. Always contact the customer service of your authorized Beissbarth equipment dealer.
i
To enable action to be taken quickly, it is important to inform customer service of the specifications on the rat-
ing plate (label on the flange end of the MT 788) and the nature of the problem.
Faults
Causes
Remedy
The displays
do not light on
switch-on
1. Defective fuse or missing phase
2. Damaged fuse in electrical connection
3. Damaged fuse in control/display panel
1. Check the mains connection.
2. Replace the fuse in the electrical connection.
3. Replace the fuse in the control/display panel. In-
form customer service.
Caution:
Repeated fuse damage is an indication of a
malfunction.
1
1. Setting and calibration data lost from PCB memory
2. One or more calibration operations (setting, calibrati-
on of electronic vernier caliper/Angular width gauge)
not performed
Check and correct calibration and settings.
2
Wheel guard raised prior to completion of measurement
Wait for end of measurement before raising wheel
guard.
3
1. Backward rotation of wheel on start of measurement
2. Incorrect connection of motor
1. Check that wheel is stationary on starting and stop
it turning backwards on starting.
2. Check proper connection of motor.
4
1. No motor operation, motor does not attain the neces-
sary speed
2. Fault in electrical connection
3. Fault in PCB
1. Check mains voltage (probably too low).
2. Check electrical connection or power cord.
3. Replace the PCB.
5
1. Balance weight not attached to wheel
2. Measurement sensors not correctly connected
1. Repeat calibration from the start and attach balan-
ce weight as specified by the process.
(refer to 13.312.4).
2. Check the connection of the measurement sensors.
6
1. Wheel guard not lowered
2. Damage to wheel guard safety switch
1. Lower wheel guard with wheel attached.
2. Replace wheel guard switch.
7
Excessive phase difference between the 2 measurement
sensors
1. Check for correct attachment of
calibration weight.
2. Check machine connection; MT 788 probably not
stable and vibrating excessively.
3. Check contact between measurement sensor and
PCB.
4. Replace measurement sensor.
5. Replace PCB.
8
Inner measurement sensor not correctly connected, de-
fective or open circuit in wire
1. Check connection of left measurement sensor.
2. Replace measurement sensor.
9
Outer measurement sensor not correctly connected, de-
fective or open circuit in wire
1. Check connection of right measurement sensor.
2. Replace measurement sensor.
10
1. Measurement sensor for position recognition defective
2. No motor operation
1. Check connection of light barrier PCB.
2. Check that the light barrier PCB is protected
against light and provide a cover if necessary.
3. If the fault persists, check and if necessary replace
the light barrier PCB.
4. Check the mains connection.
11
1. Measurement sensor for phase recognition defective
2. No motor operation
1. Check connection of light barrier PCB.
2. Make sure the light barrier PCB is protected
against light and provide a cover if necessary.
3. Check and if necessary replace the light barrier
PCB.
4. Check the mains connection.
17
Weight outside setting range (weight required for balan-
cing is more than 250 g)
1. Check whether the wheel is correctly attached to
the flange.
2. Determine the outer weight position (neverthel-
ess), attach a 100 g weight and start a different
measurement.
18
Wheel data not entered
Enter wheel data before performing measurement.
Содержание MT 788
Страница 2: ......
Страница 135: ...932 655 638 2014 02 14 Beissbarth GmbH Tekniska data MT 788 135 sv ...
Страница 157: ...932 655 638 2014 02 14 Beissbarth GmbH Technische gegevens MT 788 157 nl ...
Страница 179: ...932 655 638 2014 02 14 Beissbarth GmbH Dados técnicos MT 788 179 pt ...
Страница 201: ...932 655 638 2014 02 14 Beissbarth GmbH Dane techniczne MT 788 201 pl ...
Страница 223: ...932 655 638 2014 02 14 Beissbarth GmbH Technické údaje MT 788 223 cs ...
Страница 245: ...932 655 638 2014 02 14 Beissbarth GmbH Teknik veriler MT 788 245 tr ...
Страница 271: ...932 655 638 2014 02 14 Beissbarth GmbH Технические данные MT 788 271 ru ...