932 655 638
2014-02-14
|
Beissbarth GmbH
32 | MT 788 | Commissioning
en
4.7
Calibration of MT 788
!
Calibration must be performed after initial commis-
sioning.
1.
Flange calibration.
2.
MT 788 calibration.
3.
Perform reference measurement.
i
Calibration is described in Section 12.4
4.6
Compressed air connection
1.
Connect the MT 788 to the compressed air supply.
651003-05 _Rf
2.
Set a pressure of between 8 bar and 10 bar.
First pull the pressure reducer (red knurled
screw) upwards and then turn to set the pressure
to between 8 and 10 bar.
Check the pressure on the pressure gauge.
!
The pressure must never exceed 10 bar!
4.5
Checking the direction of rotation
1.
Check that the MT 788 is correctly connected to the
mains power supply.
2.
Switch on the MT 788 with the On/Off switch.
3.
Close the wheel guard or press the <START> button).
The shaft rotates.
4.
Check the direction of rotation of the shaft.
i
The correct direction of rotation is indicated by a
yellow arrow on the MT 788. This arrow is situated
to the right of the flange.
i
If the direction of rotation is incorrect, the MT 788
comes to an immediate stop and displays the error
message (see section 11).
Содержание MT 788
Страница 2: ......
Страница 135: ...932 655 638 2014 02 14 Beissbarth GmbH Tekniska data MT 788 135 sv ...
Страница 157: ...932 655 638 2014 02 14 Beissbarth GmbH Technische gegevens MT 788 157 nl ...
Страница 179: ...932 655 638 2014 02 14 Beissbarth GmbH Dados técnicos MT 788 179 pt ...
Страница 201: ...932 655 638 2014 02 14 Beissbarth GmbH Dane techniczne MT 788 201 pl ...
Страница 223: ...932 655 638 2014 02 14 Beissbarth GmbH Technické údaje MT 788 223 cs ...
Страница 245: ...932 655 638 2014 02 14 Beissbarth GmbH Teknik veriler MT 788 245 tr ...
Страница 271: ...932 655 638 2014 02 14 Beissbarth GmbH Технические данные MT 788 271 ru ...