CHECK the integrity of the probe after having removed it from the box.
Check that the data written on the box correspond to the type of gas used.
When doing the electrical connections, follow the drawing closely.
Any use of the detector for purposes other than the intended one is considered improper, and as a
result of which BEINAT S.r.l.  therefore disclaims any responsibility for possible damages caused to
people, animals or objects.

IMPORTANT:  The  operation  test  should  not  be  carried  out  with  the  gas  tap  as  this  does  not  guarantee
a  sufficient  concentration  to  activate  the  general  alarm.

TERMS and EXPECTATIONS: The installation of the BX444-Mc probe, its ordinary and extraordinary maintenance,
and its out of service removal at the end of the functional life guaranteed by the manufacturer, must be carried out
by authorized and/or specialized personnel.
Do not allow it to become wet.
The probe can be seriously damaged when immersed in water. Remember that the probe has a protection degree IP44.
Do not drop it.
Heavy knocks or falls during transportation or installation can damage the appliance.
Avoid abrupt temperature fluctuations.
Sudden temperature variations can cause condensation and the probe could work poorly.
Cleaning
Never clean the device with chemical products. If necessary, wash with a moist cloth.
Absolutely avoid using any cloth dipped in thinners, alcohol and chemical detergents.

Precautions

Main Power Supply boxed version  ................................................................  110/230VAC 50/60Hz ±10%
Secondary Power Through Battery Max 2,2 Ah (Optional) ..................................................... 12 V            ±10%
Battery  Charger  max 2.2  Ah  ....................................................................................................  Controlled
Power  Demand    ...........................................................................................................9,3W  max  @  230V
Power  Demand  ................................................................................................................5W  max  @  12V
Relay Contact  Range  ................................................................... 10A 250VAC  resistive  - 5A 30Vdc resistive

1

st

 Pre  Alarm  .........................................................................................  Set to 8% of L.E.L. or 120ppm  CO

2

nd

 Pre Alarm  ....................................................................................... Set  to 13% of L.E.L. or 200ppm  CO

Final Alarm  ......................................................................................... Set  to  20%  of L.E.L. or  300ppm  CO
..
Monitored  Gas  Indication    ...............................................................................  Through  backlit  color  display
Number of Conventional Sensors   that  can be  connected .......................................................................  4
Micro-switches  to  include  or  exclude  the probes  ................................................................  1  per  each  probe
Connectable probes ............................. Semi-conductor, Catalytic, Electrochemical cell, Pellistore, Infrared Rays
Type  of  faults  detected by  Fault  Circuit    ...................................................  Interruption, short  circuit, or  wear
Input Signal .........................................................................................................  4 ÷ 20 mA  on 220 ohm
Device  Accuracy  ........................................................................................................................  1%  FS
Response  Time    ............................................................................................................................  <  2”
Control  Unit  ....................................................................................................................  microprocessor

Functioning  Temperature ...................................................................................................  -10°C ÷  +60°C
Waiting, blinking period  ........................................................................................................... 90 seconds
Manual  Test    ............................................................................................................................  Built  in
Max.  distance  between  probes  and  unit  ..........................................................................................  100  m
Cable  diameter  for  connecting  probes  .............................................................................................  1  mm

2

Connection: The cable of connection of the probe must not be installed together with the power cables.
Otherwise, make sure to use a shielded cable
Size  DIN  EN  50092    ...........................................................................................................  144*144*110
Degree  of  Protection  .....................................................................................................................  IP44
Warranty.......................................................................................................................................3 years

Technical Specifications

Page  2

WARNING!  Actions  to  be  taken  in  case  of  alarm

G a s
1)  P
ut  out  all  free  flames.
2)  Close  the  main  gas  tap  or  the  LPG  cylinder  tap.
3)  Do  not  turn  any  lights  on  or  off;  do  not  turn  on  any  electrical  device  or  appliance.
4)  Open  windows  and  doors  in  order  to  increase  ventilation.
If  the  alarm  stops,  its  cause  must  be  found  and  the  relevant  consequent  measures  taken.
If  the  alarm  continues  and  the  cause  of  gas  presence  cannot  be  found  or  removed,  abandon  the  building
and  call  the  emergency  services  when  outside  (fire  department,  distributors,  etc.)

IMPORTANT: The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration
to  activate  the  general  alarm.

Warning  !!

If  you  have  the  following  symptoms:  vomiting,  sleepiness,  or  else,  go  to  the  closest  first  aid
station  and  inform  the  operators  that  you  could  have  been  poisoned  by  Carbon  Monoxide

or

by an excess or deficiency of oxygen

MAINTENANCE
The  user  periodically  (every  6  months)  must  perform  a  check  of  the  operation  of  the
control  unit  by  spraying  a  suitable  test  gas  at  the  base  of  the  probes  connected  until  the
alarm  condition  is  reached.
•  At  least  once  a  year  make  a  more  accurate  check  by  a  specialist  technician.
•  Disabling  the  detector  must  be  carried  out  by  qualified  personnel.

Содержание BX444-Mc

Страница 1: ...mall underground car parks The BX444 M control unit has three danger levels 1st LEVEL 1st Alarm This was set to 8 of L E L 120ppm 2nd LEVEL 2nd Alarm This was set at 13 of L E L 200ppm 3rd LEVEL Main Alarm This was set at 20 of L E L 300ppm For oxygen the centrol unit BX444 Mc presents three levels of danger which are 1st Pre Alarm Both in deficiency and excess of Oxygen 2nd Pre alarm Both in defi...

Страница 2: ...f Conventional Sensors that can be connected 4 Micro switches to include or exclude the probes 1 per each probe Connectable probes Semi conductor Catalytic Electrochemical cell Pellistore Infrared Rays Type of faults detected by Fault Circuit Interruption short circuit or wear Input Signal 4 20 mA on 220 ohm Device Accuracy 1 FS Response Time 2 Control Unit microprocessor Functioning Temperature 1...

Страница 3: ...FREON 0 300 ppm 4 20 mA 5 Yes Yes SGF108 Elettrochimica IP64 Zone 2 H2S 0 300 ppm 4 20 mA 5 Yes Yes SGF110 Electrochemical IP64 Zone 2 C O 0 300 ppm 4 20 mA 5 Yes Yes SGF112 Catalytic IP64 Zone 2 Hydrogen 0 100 LEL 4 20 mA 5 Yes Yes CO100r Electrochemical IP55 Tertiary C O 0 300 ppm 4 20 mA 5 Yes Yes CO100Ar Electrochemical IP66 Zone 2 C O 0 300 ppm 4 20 mA 5 Yes Yes SG800duct Catalytic IP66 Zone ...

Страница 4: ... LED blinks when one of the connected probes is faulty if there is an interruption in the cable connection or if an error was made during wiring When this LED is blinking the device is no longer capable of detecting To reactivate the device the damaged probe must be repaired or disabled using the internal micro switch see chapter 6 paragraph A and then the RESET button must be pressed 11 EXPLOSIVE...

Страница 5: ...000 a ppm LEL 1 2 3 4 d b 00LEL 300ppm The blu display shows the percentage of oxygen normal condition 20 6 20LEL FAU The green display shows an absence of leakage of gas normal conditione The display shows with red color a concentration of explosive gases in LEL greater than a threshold alarm The display shows with red color a concentration of toxic gases ppm greater than a threshold alarm The ye...

Страница 6: ... connections according to Regulations in force keeping in mind that the signal cables should be laid separate from the power cables An automatic cut off switch appropriately identified as devicesectioning of the detector should be incorporated in the electrical system adequatelylocated and easily accessible Electrical Connections Diagram of the terminal block relay Power supply 110 230 VAC PH N 4 ...

Страница 7: ...nnection examples Power supply 230 12V Diode 1N 5406 1 2 3 4 5 6 7 8 3 2 1 Probe 1 3 2 1 Probe 2 3 2 1 Probe 3 3 2 1 Probe 4 R1 R2 R3 R4 Solenoid valve GAS and Sirens 12 VDC 12 V If a 12Vdc solenoid valve which does not work well is connected to the BX444 Mc Direct connection of 12VDC solenoid valves or sirens to the BX444 Mc is not permitted An external power unit must always be used The BX444 Mc...

Страница 8: ...On the next pass the LED probe will be maintained again and the alarm will be issued In case of fault The LED of the relevant probe starts blinking and remains lit The display will show the FAU Fault fixed indication and the buzzer will issue a continuous sound until 1 The repair has been carried out 2 The relevant probe has been disabled using the micro switch 1 2 4 3 Sensors Probe Identification...

Страница 9: ...memory and the relay switches off when the connected probe no longer detects gas In compliance with the rules this function becomes active only when you select the detection of Toxic Gases reading in ppm Switch 2 4 Selecting of the control unit in oxygen detection mode By setting the micro switch to ON the device is ready to detect the oxygen The display changes color and becomes BLU ATTENTION Sel...

Страница 10: ...ition of the detection sensors You can connect many types of remote sensors to this unit Therefore they should be positioned at different heights depending on the type of gas to be detected These heights are 30 cm from the lowest point of the floor in order to detect Heavy gases L P G etc 30 cm from the highest point of the ceiling in order to detect light gases Methane etc 160 cm from the lowest ...

Страница 11: ...rectly connected If the Fault LED lights up Check that the connecting cables from the BX444 Mc to the probes are intact that the probes are properly powered and that the signal cable is correctly connected If the Over Load Probe LED lights up Check that the power polarity has not been inverted that no short circuit is present that the probes were not damaged during installation that no excessive c...

Страница 12: ...r example sales points in case you buy a new and similar product local collection points waste collection center local recycling center etc By ensuring this product is disposed of correctly you will help prevent potential negative consequence for the environment and human health which could otherwise be caused by inappropriate waste handing of this product The recycling of materials will help to c...

Отзывы: