MAINTENANCE
The user periodically (every 6 months) must perform a check of the operation of the
control unit by spraying a suitable test gas at the base of the probes connected until the
alarm condition is reached.
• At least once a year make a more accurate check by a specialist technician.
• The disabling of the detector must be carried out by qualified personnel.
Installation of the detector does not exonerate. From the observance of all rules regarding the characteristics,
installation and use of gas appliances. The ventilation of the premises and the discharge of the combustion products
prescribed by UNI norms as from ART. 3 LAW 1083/71 and the relevant provisions of law
.
Protec ZONE Detected Working Automatic
Probe
Sensor Degree Suitable for GAS
Range OutPut Calibration Calibration Relay
SG500
Catalytic
IP30
Hausold
CH4-LPG
0÷100% LEL 4÷20 mA
±5 %
NO
NO
SG544
Catalytic
IP44
Tertiary
CH4-LPG
0÷100% LEL 4÷20 mA
±5 %
NO
NO
SGM595
Catalytic
IP55
Tertiary
SeePricelist
0÷100% LEL 4÷20 mA
±5 %
Yes
NO
SGM595/A
Catalytic
IP66
Zone 2
SeePricelist
0÷100% LEL 4÷20 mA
±5 %
Yes
NO
SGM533
Catalytic
IP55
Tertiary
SeePricelist
0÷100% LEL 4÷20 mA
±5 %
Yes
Yes
SG800
Catalytic
IP66
Zone 2
SeePricelist
0÷100% LEL 4÷20 mA
±5 %
Yes
Yes
HCF100
SemiConduct
IP55
Tertiary
Freon
0÷300% ppm 4÷20 mA
±5 %
NO
Yes
SG895
Catalytic
ATEX
Zone 1
SeePricelist
0÷100% LEL 4÷20 mA
±5 %
Yes
NO
SG580
Catalytic
IP66
Zone 2
SeePricelist
0÷100% LEL 4÷20 mA
±5 %
NO
NO
SGF100
Catalytic
IP64
Zone 2
Methane
0÷100% LEL 4÷20 mA
±5 %
Yes
Yes
SGF102
Catalytic
IP64
Zone 2
LPG
0÷100% LEL 4÷20 mA
±5 %
Yes
Yes
SGF104
Optical Fluo
IP64
Zone 2
Oxigen
In %
4÷20 mA
±5 %
Yes
Yes
SGF106
SemiConduct
IP64
Zone 2
Freon
0÷300% ppm 4÷20 mA
±5 %
Yes
Yes
SGF108
Electrochimical IP64
Zone 2
H2S
0÷300% ppm 4÷20 mA
±5 %
Yes
Yes
SGF110
Electrochimical IP64
Zone 2
C O
0÷300% ppm 4÷20 mA
±5 %
Yes
Yes
SGF112
Catalytic
IP64
Zone 2
Hydrogen
0÷100% LEL 4÷20 mA
±5 %
Yes
Yes
CO100r
Electrochimical IP55
Tertiary
C O
0÷300% ppm 4÷20 mA
±5 %
Yes
Yes
CO100Ar
Electrochimical IP66
Zone 2
C O
0÷300% ppm 4÷20 mA
±5 %
Yes
Yes
SG800
duct
Catalytic
IP66
Zone 2
CH4-LPG
0÷100% LEL 4÷20 mA
±5 %
Yes
Yes
CO200
duct
Electrochimical IP66
Zone 2
C O
0÷300% ppm 4÷20 mA
±5 %
Yes
Yes
Legend
Households: Family Housing. Boiler rooms max 70 kW-h
Tertiary Rooms: Large Boiler Rooms, Offices, Material Deposits, Industrial Kitchens, Large Building Complexes, Factories.
Zone 2- Mixed IP65 ATEX: Locations with a high probability of leekage, High Risk Areas, Rooms for which the applicable Standards are
in force.
Area 1- Hazard ATEX: High Risk Areas, Rooms for which Regulations are in force, Tank Deposits, Control Valves or Joint Railings
WARNING! Actions to be taken in case of alarm
Gas
1) Put out all free flames.
2) Close the main gas tap or the LPG cylinder tap.
3) Do not turn any lights on or off; do not turn on any electrical device or appliance.
4) Open windows and doors in order to increase ventilation.
If the alarm stops, its cause must be found and the relevant consequent measures taken.
If the alarm continues and the cause of gas presence cannot be found or removed, abandon the building and call
the emergency services when outside (fire department, distributors, etc.)
IMPORTANT: The operation test should not be carried out with the gas tap as this does not guarantee a sufficient
concentration to activate the general alarm.
Warning !!
If you have the following symptoms: vomiting, sleepiness, or else, go to the closest first aid station
and inform the operators that you could have been poisoned by Carbon Monoxide,
or by an excess
or deficiency of oxygen