4 Operation
4.1 Directions of operation panel
4.1.1
Illustration of operation panel
4.1.2
Function of push buttons
1
Power switch
(knob switch) Power switch is mounted on the right side of
control cabinet. When the switch points at the position 1, the power supply is
connected through, the system is power on and the power indictor lights; points at the
position 0 to cut off power, the indicator off.
a. When power is on, all of electrical equipments and hydraulic system are
in a state of stand-by.
b. When need to stop the machine, usually just turn the knob to the
position 0; if no work for a long time, pull off the power plug.
c. Only this switch is at the position 1, all of electrical equipment and
hydraulic system are able to work.
2
Heating button
(self-lock button)
Press the button, the heat press
plates start heating and the heating indictor is lighting; press again (reset) to
stop heating and the heating indictor light is off. Auto/man all are effective.
Note: it can heat only in selecting work, otherwise PLC alarms. If PLC alarms, cut
off power then restarting.
3
Heat press start button
(return button) Under automatic mode, press
down this button for
1 second
, auto-cycle starts; automatically finishes one work cycle
based on the set pressure and set time. Press once again to start second cycle. It is
effective at automatic mode.
4
Cool press start button
(return button) Under automatic mode, press
down this button for
1 second
, cool press auto-cycle starts; automatically finishes one
work cycle based on the set pressure and set time. Press once again to start second
cycle. It is effective at automatic mode.
Note: when the heat press system compensates press, or heat press plates are going
up/down, cool press action does not start until heat press action is finished. When cool
press is acting, if heat press compensates press or up/down, the action of cool press
will be suspended, after the action of heat press is finished, the action of cool press
acts continuously.
5
Emergency Stop button
In an emergency situation, can press the
button to cut off heating and the motor of oil pump.
a. If there is any abnormal status in works, press this button immediately to
stop the machine, so that find out the reason caused the abnormal status.
b. After eliminating fault, turn the button in clockwise. When the spring
clicks springing back, stop turning and release the button. It is relieved of
emergency stop, self-lock resets.
c. After terminating an emergency stop, press the start button to restart
operating.