Installation
4. Connect the cables in the specified order, according to the drawing and steps
below.
Caution:
•
Ensure that the Panel PC and the controller system have the same electrical
grounding (reference voltage level), otherwise errors in communication may
occur.
•
The Panel PC must be brought to ambient temperature before it is started up. If
condensation forms, ensure that the Panel PC is dry before connecting it to the
power outlet.
•
Ensure that the voltage and polarity of the power source is correct.
•
Use only shielded communication cables.
•
Separate high voltage cables from signal and supply cables.
24V DC
RS422/RS485
24V DC
1
CF CARD
B
A
C
D
RS232
Controller
Power
Ethernet
–
Connect cable A.
–
Connect cable B, using an M5 screw and a grounding conductor (as short
as possible) with a cross-section of minimum 2.5 mm
2
.
–
Connect cable C.
–
Connect cable D.
5. Carefully remove the laminated film over the Panel PC display, to avoid static
electricity that could damage the panel.
3.2.1
Other Connections and Peripherals
Cables, peripheral equipment and accessories must be suitable for the application
and its environment. For further details or recommendations, please refer to the
supplier.
Beijer Electronics, MAEN043
12