Beijer Electronics Frequency Inverter BFI-E3
KI00369B 2019-09
www.beijer.se www.beijer.no
www.beijer.dk
www.beijerelectronics.de www.beijerelectronics.com www.beijerelektronik.com.tr
3 (24)
4 Installation
The drive should be mounted in a vertical position only on a flat, flame resistant vibration
free mounting using the integral holes. IP66 is allowed for outdoor mounting. But it is
recommended having an external roof to avoid snow directly on drive. BFI will not start if
ambient temperature is below -20°C. See User Manual BFI-E3 for more details.
4.1 Physical dimensions IP20
BFI-E3- IP20
Drive
size
A
Height
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
Depth
[mm]
G
Width
[mm]
H
[mm]
I
[mm]
J
[mm]
Weight
[kg]
1 x 230 V
3 x 380-480 V
0023-0070
[0,37-1,5 kW]
0022-0041 [0,75-1,5kW]
1
173
160
109
162
5
123
83
50
5,5 10
1,0
0070- 0105
[1,5-2,2 kW]
0041-0095 [1,5-4,0 kW]
2
221
207
137
209
5.3
150
110
63
1,7
0153/ 4,0 kW 0140-0240 [5,5-11kW]
3
261
246
-
247
6
175
131
80
3,2
No
0300-0460 [15-22kW]
4
420
400
-
400
8
212
171
125 8,2 14,8
9,1
No
0610-0720 [30-37kW]
5
486
463
226
222
175
18,1
NOTE
1x230 BFI-E3-0070 and BFI-E3-0041 are without brake transistor for Size 1 and Size2 with.
Mounting bolts for Size1 to Size 3 are 4xM4 and 4xM8 for Size4 and Size5.
Control Terminal Torque Settings of 0.8Nm.
Power Terminal Torque Settings: Size1-3 = 1 Nm, Size4=2.0 Nm, Size5=4.0 Nm.
Drive IP-class
and
Size
X [mm]
Above &
Below
Y [mm]
Either
Side
Z [mm]
Between
drives
Minimum
Airflow
[m3/min]
IP20, size 1
50
50
33
0,14
IP20, size 2
75
50
46
0,27
IP20, size 3
100
50
52
0,74
IP20, size 4
100
50
52
1,48
IP20, size 5
200
25
70
1,28
IP66, All sizes
200
10
0
0
Z means that BFI can be mounted side-by-side. Minimum airflow is