18
Fig. 2.11: <EDIT> menu in METER mode
The eight parameters in the <PROCESS> menu can be edited while visually monitoring the effects of the
edits on the level meters. Softkey D (IN/OUT) toggles the display between the input and output levels. Your
selection is indicated by a highlighted IN or OUT in the pictogram. Use the softkeys A and B to select the
parameter to be edited. The Left and Right cursor keys can be used to switch between the individual bands (1
to 6), as well as to change between the left and right channels when in 2-channel mode. Use the Up and Down
cursor keys to edit the selected parameter. Softkey C (SOLO) lets you listen to the current band being
affected by the selected parameter separately. The meter also displays only the selected band while in solo
mode. The other displays are disabled while the solo mode is active.
2.4 Setup level 1
Press the SETUP key to access setup level 1. The LED above the SETUP button will start to flash. This level
contains all of the settings which are related to the actual signal processing. Pressing the SETUP key will take
you to the input/output menu <IN/OUT> and the band menus (BAND 1 to 6). The LEFT and RIGHT entries
in the first line let you switch between the left and right channels. If stereo mode is activated in setup level 2,
this display will not be present, i.e. both channels are linked and will be edited at the same time. The param-
eters are selected using the cursor keys in all setup menus. Parameters can be modified and modes switched
using the softkeys marked + and -. The two outer softkeys can be used to make modifications over a wider
range than the inner ones. In each case, pressing the opposite key while holding the key being used will
accelerate the operation being carried out. Pressing the PROCESS or METER keys will cause the unit to exit
from either setup level.
+
All of the SETUP settings are stored when switching off the ULTRA-DYNE PRO and remain
unchanged until the next time you edit them.
2.4.1 Input/output menu
Fig. 2.12: <IN/OUT> menu in setup level 1
This window is split vertically, with the parameters related to the input on the left and the output on the right.
The input side:
LEFT/RIGHT
The selected channel is displayed here. The channels can be toggled with the Plus or Minus softkeys.
INGAIN
The input gain can be adjusted in 1 dB increments from -24 to +24 dB.
TUBE TYPE
Four different Tube Types are available for the Tube Emulation: 12AX7, 12AY7, EL34 and EL84.
TUBE PROCESS
The Tube Process value determines the degree of tube-type distortion to be added to the signal. The value
2. OPERATION