Application Note:
PLC program execution will be interrupted when values for JOG parameters 15 and 16 are
changed.
Pr.79
PLC Forward/Reverse Motion
Factory Setting: 00
Settings 00
to
127
This parameter determines the direction of motion for the multi-speed Pr.17 to Pr.23 and
Master Frequency. The original direction of Master Frequency will become invalid.
Note: A 7-bit binary number is used to program the forward/reverse motion for each of the 8
speed steps (including Master Frequency). The binary notation for the 7-bit number must
be translated into decimal notation and then entered in Pr.79.
1
2
3
4
5
6
7
Weights
Bit
0=Forward
1=Reverse
Direction of 1st
Pr.17
speed for
Direction of 2nd
Pr.18
speed for
Direction of 3rd
Pr.19
speed for
Direction of 4th
Pr.20
speed for
Direction of 5
Pr.21
th speed for
Direction of 6
Pr.22
th speed for
Direction of 7
Pr.23
th speed for
Example:
1
2
3
4
5
6
7
Weights
Bit
0=Forward
1=Reverse
Forward motion of Pr.17 multi-speed1
Reverse motion of Pr.18 multi-speed2
Forward motion of Pr.19 multi-speed3
Forward motion of Pr.20 multi-speed4
Forward motion of Pr.21 multi-speed5
Reverse motion of Pr.22 multi-speed6
Forward motion of Pr.23 multi-speed7
0
1
0
0
0
1
0
Direction
The setting value=bit7 x 2
6
+bit6 x 2
5
+bit5 x 2
4
+bit4 x 2
3
+bit3 x 2
2
+bit2 x 2
1
+bit1 x 2
0
= 0 x 2
6
+1 x 2
5
+0 x 2
4
+0 x 2
3
+0 x 2
2
+1 x 2
1
+0 x 2
0
= 0+32+0+0+0+2+0+0
= 34
Pr.80
Identity Code of the AC Motor Drive
Factory Setting: ##
Settings Read
Only
This parameter displays the identity code of the AC motor drive. The capacity, rated
current, rated voltage and the max. carrier frequency relate to the identity code. Users can
use the following table to check how the rated current, rated voltage and max. carrier
frequency of the AC motor drive correspond to the identity code.
B550
Series
sensorless vector frequency drive
Содержание B550-2001
Страница 1: ...B550 Series Sensorless Vector Frequency Drive Installation Quick Start Manual ...
Страница 2: ......
Страница 6: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Страница 8: ...1 2 1 4 External Parts and Labels B550 Series sensorless vector frequency drive ...
Страница 20: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Страница 26: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Страница 92: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Страница 94: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Страница 100: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...
Страница 116: ...This page intentionally left blank B550 Series sensorless vector frequency drive ...