A – 7: Calculations
A – 7.1: Enter Parameters
By selecting this, the controller will step you
through entering the values for Pool Volume,
whether it should use TDS for calculations,
Calcium Hardness, and Alkalinity. Once the values
have been entered, the calculated LSI & Ryzner
reading will appear in the menu and on the display.
A – 7.2: LSI Setup
Use TDS? (Op):
Selects if the controller should
use TDS for the LSI/RSI calculations.
Pool Volume (Op):
Allows you to enter the
volume of the pool.
Display RSI/LSI (Op):
Allows you to select if
the RSI/LSI information is displayed on the
routine display.
A – 8: System Configuration
Press Menu on the controller’s face panel and select
System Configuration from the menu. This will allow
you to configure the following for the system:
A – 8.1: System Info
This information menu displays the controller's
system type, serial number, firmware version
information. If a BECSys Ethernet card is
installed, the card's firmware version and the
current IP address information is also displayed.
A – 8.2: Communication
Once you have entered System Configuration,
select Communication from the menu. Under
communication, you can select from the following.
A – 8.2.1: Direct Baud Rate
(Op)
This option is only shown if a BECSys Ethernet
card is NOT installed.
Here you can choose the
desired direct connect baud rate for the system.
A – 8.2.2: Ethernet Setup
This option is only shown if a BECSys Ethernet card is
installed.
These parameters should be set to
values provided by the network’s administrators.
Enable DHCP (Mgr):
Enables/disables using
DHCP. If DHCP is enabled, the controller will
retrieve its IP address information from a
DHCP server on the network. If DHCP is
disabled, the IP address information must be set
manually via the remaining items listed here.
IP Address (Mgr):
This option is only shown if
DHCP is disabled.
Sets the controllers IP
address.
IP Netmask (Mgr):
This option is only shown if
DHCP is disabled.
Sets the controllers IP
netmask.
IP Default Route (Mgr):
This option is only
shown if DHCP is disabled.
Sets the controllers IP
default route/gateway.
TCP Port (Mgr):
Sets the TCP port to listen
for connections on. Acceptable values are
1024-1089 and 1091-65535.
SMTP Server Addr (Mgr):
Sets the email
SMTP server address used by alarm call-out to
send email and text messages.
SMTP Server Port (Mgr):
Sets the email
SMTP TCP port. This value should be set to
25 unless otherwise instructed by a network
administrator.
DNS Server 1 (Mgr):
Sets the IP address for
the primary DNS server. Required for email
call-outs.
DNS Server 2 (Mgr):
(Optional) Sets the IP
address for the secondary DNS server which is
only used if DNS server 1 cannot be contacted.
C – 8.2.3: Call Out Setup
This option is only shown if a BECSys Ethernet card or
modem is installed.
Here you can set the
parameters for the alarm call-out functions.
Call Out Enable (Op):
Choose to enable or
disable call outs.
Call Start Time (Op):
Sets the time the
controller will start allowing call outs.
Call End Time (Op):
Set the time the
controller will stop allowing call outs. Set this
and Call Start Time to same value for 24 hour
callouts.
Ack. Page outs (Op):
Allows the controller to
determine if somebody is responding to the
page. If somebody receives the page and calls
the controller this stops the controller from
calling the remaining page phone numbers.
Pre-Delay (Op):
Sets the amount of time the
controller will delay to allow for alarm to reset
before calling out.