Product Description & Operating Manual EMS 13x / 23x / 33x
Beckmann GmbH © 2001
Page 19
3.2 The EMS timer programming parameters
Programming additional parameters happens in the same way as described above. A list of all
programming parameters sorted according to parameter level is shown below. References to
other parameters within a parameter description is shown by sub-menu (s M) and parameter
number (N). For example, the maximum time is found in sub-menu 4 parameter 1, or
abbreviated as M4N1. Parameter values are shown in brackets. The letter [x]
Þ
in front of the
arrow shows the parameter type as described in table 4.
3.2.1 Sub-menu 1 – Master card
1.
Cash daily[A]
Þ
This parameter sums the total of cash tanning purchases for the timer per
day. [0,00..167.772,15€] If the automatic clear parameter (M6N4) is set to YES, the counter is
deleted every day at midnight. This applies to all daily counters. All daily counters can be
deleted together with the Clear day cash parameter (M6N2).
2.
Tokens daily [A]
Þ
Sums the value of daily token purchases [0 .. 65535 tokens]. To calculate
the € value of this parameter, this value needs to be multiplied with the token value parameter
(M3N10).
3.
Card daily
[A]
Sums daily value of card purchases.
4.
Overpay
[A]
Þ
Sums overbookings [0,00..655,35€]. An overbooking occurs if the customer
inserts a valuable coin shortly before the maximum time is reached. If, for example, 29 € have
been inserted and the maximum value is 30 €, inserting a 2 € coin results in an overbooking of
1 €.
5.
Customers daily
[A]
Þ
Number of customers per day [0..65535]. Delete with red key.
6.
Cash total [A]
Þ
Total cash payments for tanning on the timer [0,00..167.772,15€].
7.
Tokens total[A]
Þ
Number of inserted tokens [0..65535 tokens].
8.
Card total [A]
Þ
Sum of all card purchases [0,00..167.772,15€].
9.
Customers total [A]
Þ
Number of customers[0..65535].
10.
Charge daily [A]
Daily amount of card recharged with coins from customers or personnel.
11.
Charge total
[A]
Þ
Total amount of card recharged with coins from customers or personnel.
12.
Personnel card [A]
Þ
Purchased tanning from personnel cards
3.2.2 Sub-menu 2 – Operating hours
1.
Operating hours 1 [A]
Þ
Total device operating time [0..65535,59 h].
2.
Operating hours 2
[C/E]
Þ
Counts backward to 0 starting at preset 2 (M2N4) [65535,59..0 h].
You can increase and decrease the preset value in 1 hour intervals with the green and red keys
respectively. If the B2 warning parameter (M4N10) is set to YES, a red dot will be displayed in
the upper left as soon as this parameter reaches zero (and the device is free). Pressing the
green and red keys simultaneously resets the parameter to the preset 2 value.
3.
Operating hours 3
[C/E]
Þ
see Operating times 2
4.
Preset 2
[B]
Þ
[0..65535 h]. You can increase and decrease this value in 1 hour intervals with
the green and red keys respectively.
5.
Preset 3
[B]
Þ
see Preset 2
6.
Test run [A]
Þ
Counts the amount of test runs [0..65535].
7.
Master card recharge [A]
Þ
Shows the amount recharged with the master card. Only
amounts recharged with the master card are reflected in this parameter. Debits from customer
cards are not reflected in this parameter.
8.
Variety card charging [A]
Þ
This parameter shows the amount recharged onto customer
cards with an appropriately programmed variety card.