Product overview
EL33xx-00x0
22
Version: 4.2
2.2.2
Technical data
Technical data
EL3314-0002
Number of inputs
4
Connection technology
2-wire
Maximum cable length to the thermocouple
30 m (
)
Input filter limit frequency
1 kHz typ.; depending on sensor length, conversion time, sensor type
Conversion time
approx. 1.6 s up to 5 ms, depending on configuration and filter setting, default: ap-
prox. 110 ms at 50/ 60 Hz
Power supply for electronics
via the E-bus
Current consumption via E-bus
typ. 200 mA
Distributed Clocks
-
Voltage measurement
Measurement range (FSV)
± 78 mV
± 2.5 V
Measurement error @ 50 Hz and 23°C ambient
temperature
± 25 µV (0.033% FSC)
tbd
Resolution
1 µV per digit
Temperature coefficient
tbd
tbd
Temperature
measurement
Wiring fail indication
yes
Temperature measurement
Type/ measurement range
Highest temperature value represent the
FSV
(used: ± 78 mV voltage measurement
range)
Measurement error @ 50 Hz filter and
23°C ambient temperature
Typ B: +200...+1820 °C
±5.0 °C
Typ E: -270...+1000°C
±1.8 °C
Typ J: -210...+1200 °C
±1.8 °C
Typ K: -270…+1372 °C
(default)
±1.8 °C
Typ L: -50...+900 °C
±1.8 °C
Typ N: -270…+1300 °C
±2.5 °C
Typ R: -50...+1768 °C
±4.0 °C
Typ S: -50...+1768 °C
±4.0 °C
Typ T: -270…+400 °C
±1.8 °C
Typ U: -50...+600 °C
±1.8 °C
Typ C: 0...+2329 °C
±3.5 °C
The given measuring error results from several factors, i.a. the measuring error of
the voltage measurement specified above and the accuracy of the temperature
measurement at the cold junction.
Resolution
Internal: 24 bit
Temperature representation: 0.1/0.01/0.001 °C per digit, default 0.01°C
Temperature coefficient
tbd
Bit width in the process data image
max. 24 byte input
Configuration
via TwinCAT System Manager
Electrical isolation
2,500 V functional isolation (testing voltage 7s channel/ channel and channel/ field-
bus, production test)
Recommended operating voltage range (ground
related)
Temperature and voltage measurement
range
Depending on the normative application
environment with consideration of the
above stated electrical isolation
Recommended signal range
(differential)
see temperature measurement in this ta-
ble
Destruction limit
(ground related)
2.5 kV (Testing voltage production test)
Destruction limit
(differential)
30 V
Special features
DisableWireBreak Detection, voltage measurment
Weight
approx. 60 g
Note: FSV = full scale value
Содержание EL33-00 Series
Страница 2: ......
Страница 6: ...Table of contents EL33xx 00x0 6 Version 4 2...
Страница 17: ...Product overview EL33xx 00x0 17 Version 4 2 Fig 10 EL3312 Fig 11 EL3314...
Страница 18: ...Product overview EL33xx 00x0 18 Version 4 2 Fig 12 EL3314 0002 Fig 13 EL3314 0010...
Страница 60: ...Mounting and wiring EL33xx 00x0 60 Version 4 2 4 12 3 EL3314 EL3314 00xx LEDs Fig 43 EL3314 Fig 44 EL3314 0002...
Страница 61: ...Mounting and wiring EL33xx 00x0 61 Version 4 2 Fig 45 EL3314 0010 Fig 46 EL3314 0090...
Страница 66: ...Mounting and wiring EL33xx 00x0 66 Version 4 2 4 13 3 EL3314 00x0 Connection Fig 50 EL3314 Fig 51 EL3314 0002...
Страница 103: ...Commissioning EL33xx 00x0 103 Version 4 2 Fig 100 Incorrect driver settings for the Ethernet port...
Страница 114: ...Commissioning EL33xx 00x0 114 Version 4 2 Fig 119 EtherCAT terminal in the TwinCAT tree left TwinCAT 2 right TwinCAT 3...