Operation
EJ6910
86
Version: 1.7.0
Fig. 123: Adding the TwinSAFE SC process data under the component, e.g. EL5021-0090
Additional process data with the ID TSC Inputs, TSC Outputs are generated (TSC -
TwinSAFE Single Channel).
Fig. 124: TwinSAFE SC component process data, example EL5021-0090
A TwinSAFE SC connection is added by adding an alias devices in the safety project and selecting TSC
(
TwinSAFE Single Channel
)
Fig. 125: Adding a TwinSAFE SC connection
After opening the alias device by double-clicking, select the Link button
next to
Physical Device,
in
order to create the link to a TwinSAFE SC terminal. Only suitable TwinSAFE SC terminals are offered in the
selection dialog.