Wind threshold regulator (in connection with a suitable
sensor from the controller manufacturer)
You set the wind threshold value with this regulator (between about 2 m/s and
22 m/s).
The wind threshold value can be adjusted in 11 steps. When slowly turning the
regulator, the tubular drive clicks to indicate the setting changes.
- Left stop
Stage 1, retract at low wind
+ Right stop
Stage 11, retract at very high wind
Changes made to the threshold value are transferred immediately.
When setting the threshold, ensure that no button is
pressed. When the wind speed exceeds the set wind
threshold value, the sun protection system retracts and re-
mains closed. The sun protection system can only be exten-
ded again after the wind speed has remained below the
threshold value for approx. 15 minutes.
The set threshold applies to all channels.
TEST mode
The TEST mode is activated by adjusting the threshold value. It automatically
ends after about 15 minutes. In TEST mode, the time for which the wind is
monitored is shortened.
Factory default settings
Wind threshold value
Left stop (about 2 m/s)
20 - en
Содержание Centronic SunWindControl SWC245-II
Страница 13: ...13 de ...
Страница 25: ...25 en ...
Страница 49: ...49 nl ...
Страница 50: ...50 ...
Страница 51: ...51 ...
Страница 52: ......