Caution
In order to operate a roller door in maintained operation,
the system must be equipped with a closing edge safety
device. Please ensure that main and auxiliary closing
edges are sufficiently protected and the permitted closing
edge forces are not exceeded!
Outdoor light
The light is switched on for 2 minutes at every door movement. The outdoor light (bulb)
is connected according to the wiring diagram.
External control sensor (IMP)
An external control sensor, e.g. key-operated push-button, can be connected to the
IMP terminals. This control sensor has the switching sequence: Up, Stop, Down, Stop
etc.
Light barrier (LS)
The potential-free relay contact (break contact) of the light barrier can be connected to
the LS terminals. If the light barrier is activated, the door is stopped and travels up-
wards briefly (reverse travel).
The light barrier only serves as object protection in accordance with EN12453.
Emergency Stop
At the Emergency Stop terminals, an anti-unrolling device and external safety limit
switches, for example, can be connected in series.
10