TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No Power
Check power source, restore
as necessary
Fuse Blown
Remove Base Panel, replace
inline fuse
Unit
will
not
operate,
ON/OFF, Switch does not
light.
Faulty Switch
Replace On/Off Switch
No air to unit
Restore air supply
Timer not cycling
Replace timer
Unit will not operate –
ON/OFF Switch is lit
Air valve not shifting
Replace air valve
Nozzle obstructed
Remove and clear nozzle
Springs
oversized
or
damaged
Replace springs
Inadequate air supply
Restore supply to 80 p.s.i.
Air leaking around door(s)
Adjust
door
latch/replace
gasket
Unit runs – will not feed
springs
Window(s) leaking
Replace windows
Supply reservoir over filled
Remove springs to restore
operating level
Unit
runs
– feed rate
inadequate
Insufficient volume in supply
reservoir
Add
springs
to
restore
operating level
Feed tube kinked, worn or
obstructed
Replace feed tube
Springs
have
been
magnetized
Remove and degauss springs
Springs dirty or oily
Remove and clean springs
Springs will not feed down
tube
Static charge
Small,
light
springs
are
subject
to
static
charge
buildup. This may become
worse
in
low
humidity
conditions. An occasional
shot of anti-static aerosol can
eliminate this problem. Take
care to not saturate the
springs. Any liquid – water,
oil or solvent will impair
spring feed rates.