4
SETUP & INSTALLATION
SETUP
All models of Becmatic Spring Feeders require a 115 volt grounded electrical outlet and 80 p.s.i.
of clean air. The unit may be plugged into any standard 115 volt outlet, or may be wired directly
to any controller with 115 volt output. In installations where the air supply exceeds 80 p.s.i., a
regulator should be provided.
The feeder should be mounted above the spring escapement to allow gravity feed of the springs
through the feed tube.
Feed tube length should be kept as short as possible to eliminate
excess backpressure, (36” maximum).
INSTALLATION OF FEED TUBE(S)
The feed tube is inserted into the outlet nozzle on the front of the feeder. The lock collar should
be adjusted to provide a secure grasp on the feed tube. Over tightening the lock collar will result
in damage to the nozzle and may impair the travel of the springs. Feed tube length should be
enough to allow a transition without kinks or sharp bends that will impede flow.
*
230 volt models are not supplied with a plug.
*
See mounting instructions.