Cubicle
Type
Pump
type
Voltage
V
Freq
Hz
Phase Max.
power
kW
Nom.
current
A
Over-
load
setting
A
Supply
cable
mm
2
Max.
fuse
IEC
A
1900 2214 09 AGS-1
560-D
SV7.1
90/1
400V+ N 50
3 ph
1.50
3.3
3.6
1.5
16
AGS
2210-D
SV7.1
90/1
380V+ N 60
3 ph
1.80
3.3
3.6
1.5
16
1900 2214 10 AGS
2860-D
SV7.3
30/1
400V+ N 50
3 ph
3.00
7.2
7.9
1.5
16
AGS
3770-D
SV7.3
30/1
380V+ N 60
3 ph
3.60
7.2
7.9
1.5
16
8.3
Performance data
Principal data
AGS Simplex, 50 Hz
Type
AGS 520-S
1-phase
Simplex
AGS 520-S
3-phase
Simplex
AGS 1560-S
3-phase
Simplex
AGS 2860-S
3-phase
Simplex
Free air aspired at reference
conditions
l/min
533
533
1560
2900
Motor power data based on shaft
input at reference conditions
kW
0.38
0.38
1.10
1.49
Motor power data based on shaft
input at reference conditions
hp
0.50
0.50
1.47
1.99
Mean sound pressure level at
reference conditions
dB(A)
60
60
64
69
AGS Simplex, 60 Hz
Type
AGS 650-S
1-phase
Simplex
AGS 650-S
3-phase
Simplex
AGS 2210-S
3-phase
Simplex
AGS 3770-S
3-phase
Simplex
Free air aspired at reference
conditions
l/min
750
750
2250
3770
Motor power data based on shaft
input at reference conditions
kW
0.49
0.49
1.40
1.98
Motor power data based on shaft
input at reference conditions
hp
0.65
0.65
1.87
2.65
Mean sound pressure level at
reference conditions
dB(A)
64
64
69
70
AGS Duplex, 50 Hz
Instruction book
40
Содержание AGS 1560
Страница 2: ......
Страница 11: ...Simplified schematic of a AGS Simplex installation Instruction book 9...
Страница 13: ...AGS Simplex AGS Duplex Instruction book 11...
Страница 16: ...Service diagram AGS Simplex 1 ph typical Instruction book 14...
Страница 45: ...9 Declaration of conformity Typical example of a Declaration of Conformity document Instruction book 43...
Страница 46: ......
Страница 47: ......
Страница 48: ......