Shut off all power going to header before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian traffic around the door area.

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the 

door.

ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board 

ensure you dissipate your body’s ESD charge.

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and 

cause damage to equipment.

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by 

BEA, Inc. Unauthorized disassembly or repair:

1.  May jeopardize personal safety and may expose one to the risk of electrical shock.
2.  May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

JUMPERS

PRECAUTIONS TO OBSERVE WHEN USING A ‘WET’ OUTPUT

Never change the jumper settings when the module has power connected to it or when a load is applied.

Never allow 2 different voltage sources to be connected to the load (electric strike for example) at the same 
time.  This can result in serious damage to equipment.

Always move both jumpers when changing a jumper set.

If an EL device is being powered by a separate power source, DO NOT select the ‘WET’ output option on the 
Br3-X.  If ‘WET’ is selected, the next activation of the module will send a voltage to the load and if there is 
already a voltage being applied from another source, the Br3-X and possibly the load will be permanently 
damaged.

When using the ‘WET’ output option on the Br3-X, set all desired switch positions (‘WET’ – ‘DRY’ and AC – 
DC) before the module is powered and before any loads are applied.

When DC ‘WET’ output is selected, COM terminal is po) and the ground(-) is switched between NO and 
NC.

Ensure there is no other voltage connected to the load.  Whatever the Input voltage is at the Br3-X, the output 
will correspond. The following can also be observed:

1.  If voltage Input at the Br3-X is AC, then output selection can be AC or DC.

2.  If voltage Input at the Br3-X is DC, then output selection can only be DC.

3.  The maximum load applied to Relay 1 should never exceed 1A.  If more than one device is to be 

connected, add the consumption values together for a total value.  If current is excessive, damage to 
equipment can result.

4.  On the Br3-X, the ‘WET’ output is only available at Relay 1.

When supplying Br3-X with AC input voltage and selecting Relay 1 output for ‘WET’ and DC OUTPUT 

VOLTAGE, note that the resulting DC output will be the rectified AC input voltage and therefore, about 40% 
higher than the AC input voltage (rms).

CAUTION:

 Relay 1 ‘WET’ OPTION IS ACTIVE FOR ALL FUNCTIONS!

RELAY 1 OUTPUT

DRY/WET JUMPER

2

AC OUTPUT VOLTAGE

3

DC OUTPUT VOLTAGE

4

DRY

both jumpers set to DRY

N/A

N/A

WET

1

both jumpers set to WET

both jumpers set to AC

both jumpers set to DC

NOTES

:

1.  “WET output” allows the Br3-X to supply a voltage output of up to 1 A on relay 

1 for powering maglocks or electric strikes directly from the Br3-X.  Rating of 
power supply which powers the Br3-Xmust be at least 1 A. 

2.  Default jumper settings make relay 1 DRY.
3.  AC voltage only available if Br3-Xis powered by AC voltage.
4.  DC voltage available if Br3-Xis powered by AC or DC voltage.

PRECAUTIONS

Содержание Br3x

Страница 1: ...C magnetic door position switch 10SWITCH1084 Occupied indicator lock status indicator with LED and sounder 10LEDSOUNDER PUSH TO LOCK button door lock actuator with LED 10PTLBUTTON COMPONENT DESCRIPTION PART NUMBER Assistance Required signal corridor LED with sounder 10ARS Emergency signage emergency instruction signage 70 5675 PUSH FOR EMERGENCY ASSISTANCE button emergency assistance request butto...

Страница 2: ...f the module will send a voltage to the load and if there is already a voltage being applied from another source the Br3 X and possibly the load will be permanently damaged When using the WET output option on the Br3 X set all desired switch positions WET DRY and AC DC before the module is powered and before any loads are applied When DC WET output is selected COM terminal is positive and the grou...

Страница 3: ... sequence of relay 1 and relay 2 via trigger of input 1 sequence of relay 2 and relay 1 via trigger of input 2 input 3 triggers relay 1 individually input 4 triggers relay 2 individually NL normally locked restroom sequence of relay 1 lock relay 2 door and relay 3 occupied indicators for normally locked single occupancy restrooms NU normally unlocked restroom sequence of relay 1 lock relay 2 door ...

Страница 4: ...ons Once desired function is selected press FUNC to cycle through parameters Display will toggle between parameter and its current value for 5 seconds Press3 INCR to cycle through parameter s values Repeat steps 4 7 until all function parameters are set Wait 5 seconds for Br3 X to save and display function NOTES 1 Function 00 disables the Br3 X 2 nP means no parameters are applicable for the selec...

Страница 5: ... be greater than d1 when using an electric lock 1 Trigger INPUT 2 3 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2 FUNCTION 22 NOTE Ensure INPUT 1 does not initiate the sequence and that INPUT 4 is closed when the door is closed 10 timer AVAILABLE PARAMETERS h1 relay 1 hold time rL reverse logic 1 Trigger INPUT 1 RELAY 1 will close and ho...

Страница 6: ...is open but triggers RELAY 2 immediately when the contact is closed AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time d1 delay between relays 1 2 rL reverse logic h1 must be greater than d1 when using an electric lock 1 Trigger INPUT 1 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2 29 deactivation timer FUNCTION 29 NOTE INPUT...

Страница 7: ...and hold for time h2 4 Trigger INPUT 4 RELAY 3 will close and hold for time h3 36 3 relay sequencer 1 shot AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time h3 relay 3 hold time d1 delay between relays 1 2 d2 delay between relays 1 3 h1 must be greater than d1 when using an electric lock 1 Trigger INPUT 1 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time del...

Страница 8: ...PUT 2 is triggered INPUT 1 and RELAY 1 will be inhibited until INPUT 4 door position switch is closed 55 interlock ratchet latching AVAILABLE PARAMETERS NONE 1 Trigger INPUT 1 RELAY 1 will close and hold until indefinitely 2 Trigger INPUT 1 RELAY 1 will open 3 Trigger INPUT 2 RELAY 2 will close and hold indefinitely 4 Trigger INPUT 2 RELAY 2 open FUNCTION 55 NOTE If INPUT 1 is triggered INPUT 2 an...

Страница 9: ... 4 Trigger INPUT 4 RELAY 2 will close and hold for time h2 65 2 way 2 relay sequence nL normally locked restroom AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time d1 delay between relays 1 2 h1 must be greater than d1 1 Trigger INPUT 1 RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2 2 Trigger INPUT 3 RELAY 3 will close and INPUT 1 wi...

Страница 10: ...will not function unless INPUT 4 is closed INPUT 4 should be closed when door is closed dN 3 relay sequence with day night mode AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time h3 relay 3 hold time d1 delay between relays 1 2 d2 delay between relays 1 3 1 Trigger INPUT 1 INPUT 2 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2...

Страница 11: ... programmed Incorrect jumper settings Ensure all jumpers are configured correctly for specific application Defective Br3 X Replace Br3 X Br3 X output is con stant maintained One or more of IN 1 through IN 4 have shorted Resolve respective short E1 E2 E3 E4 E5 EEPROM error Reset Br3 X and reprogram BR3 FUNCTION BR3 X FUNCTION 21 22 25 28 29 36 or 37 35 36 or 37 75 28 29 36 or 37 FUNCTION CROSS REFE...

Страница 12: ...r gate manufacturer recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label e g ANSI DASMA 102 ANSI DASMA 107 Verify that all appropriate industry signage and warning labels are in place BEA INSTALLATION SER...