75.5871.04 BR3-X 20180702
Page 5 of 12
75.5871.04 BR3-X 20180702
Page 5 of 12
11
–
ratchet / latching
AVAILABLE PARAMETERS:
NONE
1. Trigger INPUT 1.
• RELAY 1 will close and
hold indefinitely.
2. Trigger INPUT 1.
• RELAY 1 will open.
22
–
2-relay seq inhibitor
AVAILABLE PARAMETERS:
h1
- relay 1 hold time
h2
- relay 2 hold time
d1
- delay between relays 1 & 2
h1
must be greater than
d1
when using an electric lock
1. Trigger INPUT 2, 3, or 'WET'.
• RELAY 1 will close and
hold for time
h1
.
• RELAY 2 will close after
time delay
d1
and hold
for time
h2
.
FUNCTION
22
NOTE: Ensure
INPUT 1 does not initiate the
sequence and that INPUT 4 is
closed when the door is closed.
10
–
timer
AVAILABLE PARAMETERS:
h1
- relay 1 hold time
rL
- reverse logic
1. Trigger INPUT 1.
• RELAY 1 will close and
hold for time
h1
.
FUNCTION
10
NOTE: Reverse logic
allows for a Normally Closed (NC)
INPUT 1.
PROGRAMMING PARAMETERS
* see page 3 for specific parameter details *