BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA 
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor 
system installation is compliant with local, national, and international regulations, codes, and standards. 
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations 
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices.  Safety inspections must be performed during each service 
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107). 
Verify that all appropriate industry signage and warning labels are in place. 

BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

TECHNICAL SPECIFICATIONS

Supply Voltage

12 − 24 VAC/VDC ±10%

Current Consumption

30 − 130 mA (DRY output)

Temperature Rating

-15

 

 150 

°

F (-26

 

 150 

°

C)

If powered by AC voltage and using WET output to convert to DC voltage and current draw of 
device is greater than 0.9 A, the upper temperature range is 130 

°

F (54 

°

C)

Input
     Input 1, 2, 3, 4
     WET input

DRY contact
5-24 VAC/VDC ±10%

Contact Rating
     Relay 1 (DRY)
     Relay 1 (WET)
     Relay 2
     Relay 3

3 A @ 24 VAC or 30 VDC
1 A
3 A @ 24 VAC or 30 VDC
1 A @ 24 VAC or 30 VDC

Dimensions

5.2" x 2.2" x 1" (133 mm x 55 mm x 25 mm)

Housing

ABS - white translucent

Specifications are subject to change without prior notice.

All values measured in specific conditions.

PLEASE KEEP FOR FUR

THER USE – DESIGNED FOR COLOR PRINTING

©BEA

 | Original Instructions |

75.5871.04 BR3-X 20180702

Содержание Br3x

Страница 1: ...C magnetic door position switch 10SWITCH1084 Occupied indicator lock status indicator with LED and sounder 10LEDSOUNDER PUSH TO LOCK button door lock actuator with LED 10PTLBUTTON COMPONENT DESCRIPTION PART NUMBER Assistance Required signal corridor LED with sounder 10ARS Emergency signage emergency instruction signage 70 5675 PUSH FOR EMERGENCY ASSISTANCE button emergency assistance request butto...

Страница 2: ...f the module will send a voltage to the load and if there is already a voltage being applied from another source the Br3 X and possibly the load will be permanently damaged When using the WET output option on the Br3 X set all desired switch positions WET DRY and AC DC before the module is powered and before any loads are applied When DC WET output is selected COM terminal is positive and the grou...

Страница 3: ... sequence of relay 1 and relay 2 via trigger of input 1 sequence of relay 2 and relay 1 via trigger of input 2 input 3 triggers relay 1 individually input 4 triggers relay 2 individually NL normally locked restroom sequence of relay 1 lock relay 2 door and relay 3 occupied indicators for normally locked single occupancy restrooms NU normally unlocked restroom sequence of relay 1 lock relay 2 door ...

Страница 4: ...ons Once desired function is selected press FUNC to cycle through parameters Display will toggle between parameter and its current value for 5 seconds Press3 INCR to cycle through parameter s values Repeat steps 4 7 until all function parameters are set Wait 5 seconds for Br3 X to save and display function NOTES 1 Function 00 disables the Br3 X 2 nP means no parameters are applicable for the selec...

Страница 5: ... be greater than d1 when using an electric lock 1 Trigger INPUT 2 3 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2 FUNCTION 22 NOTE Ensure INPUT 1 does not initiate the sequence and that INPUT 4 is closed when the door is closed 10 timer AVAILABLE PARAMETERS h1 relay 1 hold time rL reverse logic 1 Trigger INPUT 1 RELAY 1 will close and ho...

Страница 6: ...is open but triggers RELAY 2 immediately when the contact is closed AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time d1 delay between relays 1 2 rL reverse logic h1 must be greater than d1 when using an electric lock 1 Trigger INPUT 1 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2 29 deactivation timer FUNCTION 29 NOTE INPUT...

Страница 7: ...and hold for time h2 4 Trigger INPUT 4 RELAY 3 will close and hold for time h3 36 3 relay sequencer 1 shot AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time h3 relay 3 hold time d1 delay between relays 1 2 d2 delay between relays 1 3 h1 must be greater than d1 when using an electric lock 1 Trigger INPUT 1 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time del...

Страница 8: ...PUT 2 is triggered INPUT 1 and RELAY 1 will be inhibited until INPUT 4 door position switch is closed 55 interlock ratchet latching AVAILABLE PARAMETERS NONE 1 Trigger INPUT 1 RELAY 1 will close and hold until indefinitely 2 Trigger INPUT 1 RELAY 1 will open 3 Trigger INPUT 2 RELAY 2 will close and hold indefinitely 4 Trigger INPUT 2 RELAY 2 open FUNCTION 55 NOTE If INPUT 1 is triggered INPUT 2 an...

Страница 9: ... 4 Trigger INPUT 4 RELAY 2 will close and hold for time h2 65 2 way 2 relay sequence nL normally locked restroom AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time d1 delay between relays 1 2 h1 must be greater than d1 1 Trigger INPUT 1 RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2 2 Trigger INPUT 3 RELAY 3 will close and INPUT 1 wi...

Страница 10: ...will not function unless INPUT 4 is closed INPUT 4 should be closed when door is closed dN 3 relay sequence with day night mode AVAILABLE PARAMETERS h1 relay 1 hold time h2 relay 2 hold time h3 relay 3 hold time d1 delay between relays 1 2 d2 delay between relays 1 3 1 Trigger INPUT 1 INPUT 2 or WET RELAY 1 will close and hold for time h1 RELAY 2 will close after time delay d1 and hold for time h2...

Страница 11: ... programmed Incorrect jumper settings Ensure all jumpers are configured correctly for specific application Defective Br3 X Replace Br3 X Br3 X output is con stant maintained One or more of IN 1 through IN 4 have shorted Resolve respective short E1 E2 E3 E4 E5 EEPROM error Reset Br3 X and reprogram BR3 FUNCTION BR3 X FUNCTION 21 22 25 28 29 36 or 37 35 36 or 37 75 28 29 36 or 37 FUNCTION CROSS REFE...

Страница 12: ...r gate manufacturer recommendations and or per AAADM ANSI DASMA guidelines where applicable for best industry practices Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label e g ANSI DASMA 102 ANSI DASMA 107 Verify that all appropriate industry signage and warning labels are in place BEA INSTALLATION SER...

Отзывы: