LEAK CHECKING
LIGHTING INSTRUCTIONS
1. Check all connections with a 50/50 soap and water solution to be
sure they are tight and leak proof.
2. The installation of your heater must meet all local codes and/or
gas utility requirements, or in the absence of local codes, with the
National Fuel Code ANSI Z223.1.
3. The minimum clearances to combustible construction materials
shown on page 3 must be maintained at all times.
1. Connect power cord to a properly grounded three (3) prong
120V.60Hz, extension cord. Extension Cord Wire Requirements:
6 to 10 feet (1.8 to 3 meters) long, use 18AWG conductor. 11 to
100 feet (3.4 to 30.53 meters ) long, use 16AWG conductor. 101
to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.
2. Connect heater to a proper LP cylinder.
3. Turn gas valve clockwise to OFF position.
4. Wait five (5) minutes for any gas to clear. Smell for gas; if you do not
smell gas, go to step 4.
5. Push in and turn gas control knob counterclockwise to LOW/IGN
position. This will light the burner. If needed, keep pressing control
knob until the burner lights and keep pressing and turning from OFF
to LOW/IGN on electric spark.
WARNING
• Propane is safe to use when properly handled. Careless handling
of the propane gas tank could result in a fire and/or an explosion.
Therefore:
-Always keep tank/cylinder securely fastened and in an upright
position.
-Avoid tipping the tank on its side when connected to a regulator,
since this may cause damage to the diaphragm in the regulator.
-Handle valves with care.
-Never connect an unregulated propane tank to a construction heater.
-Do not subject propane tank to excessive heat.
-Tightly close the gas shutoff valve on the propane tank after each
use.
-All fittings must be protected when disconnected from the LP tank.
-Never store a propane gas tank inside a building or in the vicinity of
any gas burning appliance.
The disconnected tank must never be stored in a building, garage or any
other enclosed area.
OPERATION
Содержание HL060F
Страница 1: ...User Manual HL060F HL125F HL150F PROPANE FORCED AIR HEATER BEPOWEREQUIPMENT COM...
Страница 2: ...2...
Страница 17: ...17 Wiring Diagram WIRING DIAGRAM...
Страница 18: ...18 Exploded View EXPLODED VIEW...
Страница 21: ...21...
Страница 24: ...21...
Страница 27: ...Vue clat e 18 VUE CLAT E...
Страница 43: ...2...
Страница 44: ...User Manual HL060F HL125F HL150F CHAUFFAGE AU PROPANE AIR FORC BEPOWEREQUIPMENT COM...