Problem
Possible Case
Solution
Fan does not turn
when electrical
connection is made.
1. No electric power to
heater.
2. Fan blade contacts
inside of heater housing.
3. Fan blade(s)bent.
4. Fan motor defective.
1. Check current to electric
outlet. If voltage is correct,
check power cord and
extension cord for cuts and
breaks.
2. Be sure that housing is not
damaged. Make sure there are
no obstructions to the fan.
3. Straighten blade(s) to match
others.
4. Replace motor.
Heater will not fire.
1. No spark at igniter.
2. Improper spark gap.
3. Bad electrode.
1. Check igniter wire. Re-attach
or tighten if loose. Check
spark module. Replace if
necessary. Check all electrical
components.
2. Set gap to 0.16”.
3. Replace spark plug.
Heater quits while
running.
1. Internal temperature too
high causing limit switch
to shut down operation.
2. Damaged control valve.
3. Dust or debris build-up
inside of heater.
1. If the heaters output is
restricted, internal temperature
becomes too high. Move
heater away from any
obstructions.
2. Replace control valve.
3. Clean inside of heater.
Troubleshooting
TROUBLESHOOTING CHART
Always be sure to follow proper maintenance procedures. By cleaning
the heater once per month during regular usage, and check spark gap at
least once per season.
TROUBLESHOOTING
Содержание HL060F
Страница 1: ...User Manual HL060F HL125F HL150F PROPANE FORCED AIR HEATER BEPOWEREQUIPMENT COM...
Страница 2: ...2...
Страница 17: ...17 Wiring Diagram WIRING DIAGRAM...
Страница 18: ...18 Exploded View EXPLODED VIEW...
Страница 21: ...21...
Страница 24: ...21...
Страница 27: ...Vue clat e 18 VUE CLAT E...
Страница 43: ...2...
Страница 44: ...User Manual HL060F HL125F HL150F CHAUFFAGE AU PROPANE AIR FORC BEPOWEREQUIPMENT COM...