Seite 29 von 33
b. The sensor works in a range of 6 metres, covers a radius of 120° and is in
operation during the ozone cleaning process and for two hours afterwards.
c. If the sensor detects people or animals in the room, ozone production is stopped
and the rapid alarm sounds, warning that the room must be vacated.
d. As soon as the sensor no longer detects movement, operation continues
automatically.
ATTENTION
Do not stay in the room under any circumstances when the unit is in the ozone
cleaning process.
After the treatment, the unit automatically runs in normal cleaning mode for 2
hours to ensure that there is no more ozone in the room.
After the two-hour normal cleaning mode, be sure to check the indicator on the
unit:
BLUE LIGHT
You are allowed to stay in the room.
ORANGE LIGHT
You have to leave the room.
MAINTENANCE AND CLEANING
Cleaning HEPA filter
We recommend cleaning the filters every 8 weeks!
To remove the dust accumulated on the outside of the air filter, use a hoover.
After cleaning, we recommend placing the filter for at least 12 hours in a well-ventilated
place, outside of living areas, preferably outdoors. This allows the particles and
substances that have accumulated in the filters to escape.
Remove and clean the filter as described below:
1. Loosening the filter housing screws
Loosen the two screws on the housing using a
Phillips screwdriver to detach the housing from the
filter holder.