![BBV Tx1000 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/bbv/tx1000/tx1000_installation-manual_2714052009.webp)
TX1000 Manual V8 September 2013
9
Status LED
The STATUS LED should flash and the monitors should show the video from Camera 1 on power up. If the
LED is permanently ON or OFF, the unit is in a fault condition. Please contact BBV technical support on:
01323 444600.
Sitting the keypad remotely from the base unit
The keypad uses RS232 9600 baud, no parity, 1 stop bit to communicate with the Tx1000 Matrix. The
keypad is full duplex will function normally up to 50m from the Matrix. Beyond this distance, any of the
proprietary cable extenders may be used (e.g. modems, fibre optics, infra red/microwave links) without any
difficulty.
Cable Connections
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Signal Ground
12V Supply
RS232 Data
RS232 Data
Frame Ground
Frame Ground
Tx1000 Main Unit
DB9-Female
Keyboard
DB9-Male
Keypad power requirements
Fully isolated 12Vdc power supply. The maximum current draw is 150mA.
Priority control between two keypad systems
Keypad one has priority over keypad two. If keypad one is only viewing but not operating any camera, then
keypad two may move that same camera. After movement commands on keypad one, there is a 20 second
lock out period before control is given to keypad two.
Text display on screen
Monitor 1:
Connect a coax cable from the M1 output on the matrix to the keypad, and connect the keypad to the
monitor’s video output using the other BNC on the keypad.
Monitor 2:
With one keypad - Connect as above, then connect a coax link from Monitor 1 to Monitor 2. This duplicates
the text onto both screens.
With two keypads – Connect a coax cable from the M2 output on the matrix to the keypad, and connect the
keypad to the monitor’s video output using the other BNC on the keypad.