TX1000 Manual V8 September 2013
21
The length of time the contacts close is also programmable. To program the length of time the contacts
close:
First determine the amount of time you wish the contacts to be closed:
Key number
Time (seconds)
Key number
Time (seconds)
1 5
9 45
2 10
10 50
3 15
11 55
4 20
12 60
5 25
13 65
6 30
14 70
7 35
15 75
8 40
16 80
Press the
key to enter the menu and select 1 and 0 and then the camera button followed by the
key number relating to the amount of time the contacts are to be closed for and then the cam button again:
To use the preset features you must have fitted a receiver that supports preset positioning; Rx400P,
Rx45X, Rx55X and preset PTZ heads or Rx10X/AL and a suitable dome camera.
Receivers with local alarms.
The Rx10X/AL dome interface has 4 local alarm inputs and the Rx45X and Rx55X have 8 local alarm inputs.
All have a single normally closed relay output that opens momentarily when a local alarm is activated. This
output can be wired to an alarm input on the Tx1000 or an alarm system.
A receiver local alarm will cause the relevant preset position to be automatically selected without the
intervention of a telemetry transmitter (see the receiver installation guide). If the transmitter also generates
a preset command, then the receiver’s preset will be overridden. To overcome this during alarm
programming use preset 16 which will prevent the Tx1000 from sending a preset command for this particular
alarm input.
The standard preset receivers can be programmed to go to a preset position 1 - 15 during an alarm.
Useful Keystrokes:
Software version
Hold # and press 1 + 0 + camera button to make the software version number, number of watchdogs and
number of resets appear on screen.