![BAYTEK GAMES SQUIGGLE Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/baytek-games/squiggle/squiggle_service-manual_2713167021.webp)
21
DIAGNOSTICS
DIAGNOSTICS
START BUTTON
Will display “Off” if large drop button is not pressed, “On” if pressed
COIN SWITCH
PULSE
Will display “On” when a coinup pulse is detected on the Aux Monster board.
Note that this may transition from “Off” to “On” and back to “Off” very quickly
during coinup and may not be noticed.
DBA PULSE
Will display “On” when a DBA pulse is detected on the Aux Monster board.
Note that this may transition from “Off” to “On” and back to “Off” very quickly
during DBA pulse and may not be noticed.
LOW TICKET
Will Display “Off” when the low ticket condition switch is not active, “On” when
active
CLOCK FREQ.
The speed of the processor clock on the main board
PI TEMP
Temperature of the processor chip on the main board
RED, GREEN, BLUE
The raw A/D values of the currently selected ball color sensor. Values range
from 0 to 1024; any given color is represented as a mix of those three values.
Usually these values are constantly updating, however, they will remain static for
a time when the blowers are started until the balls have fallen into the tube
SENSOR ID
select the top or bottom ball color sensor to use for the above Red, Green, Blue
display
TICKET
DISPENSER
Pressing the Menu Select button with this item highlighted will send the signal to
dispense one ticket to the ticket dispenser
RELEASE YELLOW
BALL
Pressing the Menu Select button with this item highlighted will activate the
yellow ball release solenoid.
SORT BALLS
Pressing the Menu Select button with this item highlighted will start a ball sort
sequence. The sequence will be for the last sensed stack of balls
START BLOWERS
Pressing the Menu Select button with this item highlighted will activate both the
yellow and red ball blowers for their normal run times
BALL DISPLAY
The left side of the screen may contain vertical rows of red and yellow “balls”.
These represent the last detected set of balls through the tube. The stack on the
left represents the top sensor and the stack on the right is for the bottom sensor.
These displays will be cleared when the blowers are started. When entering the
diagnostics page this display will show the last-played game’s data.