BayStream 7.3 Documentation Change Notice
115385-D Rev 01
BayStream Multiservice Software Version 7.3
119
Name:
wfHssiReceiveAllFrames
Object ID:
1.3.6.1.4.1.18.3.4.7.1.68
Type:
Integer
Access:
Read/Write
Default:
Disabled (2)
Description:
This attribute enables delivery of all received frames to the HSSI device driver for
processing. When disabled (2), frames less than 4 bytes in length are filtered out of the
receive frame stream before reaching the device driver. This attribute must be set to
enabled (1) to receive 3-byte frames over frame relay switched virtual circuits (SVCs).
Name:
wfHssiFrSwRnniEnabled
Object ID:
1.3.6.1.4.1.18.3.4.7.1.69
Type:
Integer
Access:
Read/Write
Default:
Disabled (2)
Description:
This attribute when enabled (1), signifies that this HSSI device driver is running frame
relay switch WAN protocol and is configured for Resilient NNI.
Statistical Data Collection
Name:
wfStatsDcAtmzVclFields
Object ID:
1.3.6.1.4.1.18.3.3.2.17.1.22
Type:
Gauge
Access:
Read/Write
Default:
0xFFFFFE00
Description:
Contains a 32-position bit mask specifying the ATM VCL counters that the BayStream
data collection software gathers, aggregates, and reports for each ATM line on which
statistical data collection is enabled. A value of 1 within the bit mask indicates that the
BayStream data collection software monitors and reports the associated ATM counter; a
value of 0 within the bit mask indicates that the BayStream data collection software
ignores the associated ATM counter. The default value (0xFFFFFE00) monitors and
reports the first 22 items in,
Figure 9
which maps specific ATM counters with specific bit
mask positions.