Baxtran CWP Скачать руководство пользователя страница 7

VI. Printing and value difference key.

1. In check weighing mode, you can press this key to change the displayed content and make 

the display convert between value difference and normal value.

    While setting the high and low limit under check weighing state, you can select percentage 

setup mode via this key, and at the same time the triangle cursor of “%” indicating symbol will 
appear.

2. Under weighing state when F1.5=0, the indicator will output serial printing signal after 

pressing this key.

VII. I/O key.
This key is used for turning on or turning off power supply, and it has other functions while 
calibrating.

7

%

I/O

POWER

While processing the operation of item 10.3, 10.4 in this manual or calibrating, you need to input the digit. 
The digit input is all fulfilled via         and          in cooperating.           refers to place-shifting key, it is used 
for selecting digit place and the selected digit place will flash. At this time if you press       , the selected 
falshing digit will change in “0 

 1 

 2 ... 9 

 0”.

For example: to input a group of digit 2345.
Step 1: Press     (C), the indicator display

Note

: While inputing the digit, first press       (C) to make the indicator display                  and then 

input the digit. It is possible that “X” refers to “    ”, “H”, “L” or “E” indicating symbol. And “0” refers 
to the flashing place.

Step 2: Press        5 times,                  is displayed
Step 3: Press          one,                 is displayed
Step 4: Press        4 times,                  is displayed
Step 5: Press          one,                  is displayed
Step 6: Press        3 times,                  is displayed
Step 7: Press           once,                  is displayed
Step 8: Press           twice,                  is displayed
Step 9: Press      (ENTER) to confirm and enter the next step.

Note:

 Under some special states, you may press [EXIT] to withdraw.

Thus a group of digit input is finished.

5. DIGIT INPUT

UNITS

0

0

UNITS

C

EXIT

BL

C

EXIT

BL

UNITS

0

UNITS

0

UNITS

0

UNITS

ENTER

T

6.1

Serial output.

6.1.1

The 5-core metal socket (figure 5) is used for Rs232 hardware interface, the socket is mounted 

on back of the indicator.

Figure 5: interface of serial signal output

6. OUTPUT AND PRINTING RS-232

5

4

2

1

3

TXD

GND

USER’S MANUAL

CWP. Bench scale

Содержание CWP

Страница 1: ...CWP Bench scale USER S MANUAL...

Страница 2: ...2 Backlight selecting 13 Auto rectifying 14 Storage battery maintaining 15 Use guide 16 Data setting and calibrating 3 3 4 6 7 7 9 9 9 9 11 12 12 12 13 13 CONTENTS USER S MANUAL CWP Bench scale Discla...

Страница 3: ...gnal input range 0mV 8mV 1 2 Zero point temperature drift 0 15 V C 1 3 Sensitivity temperature drift 10 ppm C 1 4 A D conversion resolution ration 500000 1 5 Display resolution ration 30000 1 6 A D co...

Страница 4: ...ustable support Load cell input 7 core RS 232 Interface 5 core Power supply adaptor Battery switch Seal ring assembly PCB Indicator enclosure Indicator rear cover Storage battery Battery box cover Fig...

Страница 5: ...gle cursor appears here See item 12 3 for details 7 CHARGE indicating symbol it is on when the battery is recharging 8 Auto Off indicating symbol When you switch on the auto shut off function the tria...

Страница 6: ...pressing this key and the cursor on the screen will change from G to N At this time if tou remove the goods from the scale platform the screen displays a negative value Press this key again the displa...

Страница 7: ...At this time if you press the selected falshing digit will change in 0 1 2 9 0 For example to input a group of digit 2345 Step 1 Press C the indicator display Note While inputing the digit first press...

Страница 8: ...oad mark bit D2 0 normality D2 1 overload D1 Positive and negative mark bit D1 0 positive number D1 1 negative number D0 Gross weight and net weight mark bit D0 0 gross weight D0 1 net weight State C...

Страница 9: ...ic weighing mode after power on 7 POWER ON OPERATION I O POWER You can convert between basic weighing and check weighing by pressing MODE key 8 TWO WEIGHING MODES SWITCHING MODE SET After power on the...

Страница 10: ...and low limit value in percentage mode 10 4 1 After the target weight setup is finished and the indicator displays and if the item 10 4 2 can be met i e the absolute value of the value difference betw...

Страница 11: ...splay between value difference display and normal display by pressing key and press once the display will be converted once It can reserve the shift mode unless the power supply is cut off 11 4 Three...

Страница 12: ...will display At this time place a test weight or substitute on scale platform Because the division value and Max capacity are known the decimal point place need not to be considered So at this time o...

Страница 13: ...horisation contact our sales agent in your area 15 7 If you need to re calibrate the indicator do it after the indicator is warm up for 30 minutes 15 USE GUIDE Forbid changing the data of the scale un...

Страница 14: ...s less than REV2 0 you can only choose F1 2 3 F1 5 Serial output mode with 2 options F1 5 0 printing output printer model TM U295 F1 5 1 serial output F1 6 Selecting setup value from F1 1 to F1 5 with...

Страница 15: ...ct Min display value via and then press ENTER to confirm ENTER T UNITS ENTER T If the version number is less than REV2 0 then the Max Capacity must be through digit keys The steps are as following 1 D...

Страница 16: ...t this moment you can load test weights or substitute on the platform and press ENTER the indicator will display and then carry through countdown After the countdown is finished the whole calibration...

Страница 17: ...main directory and subdirectory by Figure 12b Press to enter subdirectory and enter next main directory by confirming the last subdirectory T F1 F1 1 1 F1 2 1 F1 6 1 F2 F2 1 0 F2 F1 1 2 F2 1 0 F1 2 2...

Страница 18: ...ER T UNITS F3 F1 Inputting or selecting Max capacity Selecting decimal point Confirming zero positioning Arbitrary point loading Fixed point loading d 1 Select 1 2 or 5 by Count down SCL 09 F3 Self te...

Страница 19: ...19 USER S MANUAL CWP Bench scale...

Страница 20: ......

Отзывы: