Baxtran CWP Скачать руководство пользователя страница 14

14

16.2.1. Subdirectorios y contenido en F1

F1.1: Unit selecting, with 4 options

F1.1=1 only for choosing “kg” unit.
F1.1=2 “kg” and “lb” unit choosing and converting, when turn-on, its unit is “kg” and can be

calibrated only under “kg” unit.

F1.1=3 “kg” and “lb” unit choosing and converting, when turn-on, its unit is “lb” and can be

calibrated only under “lb” unit.

F1.1=4 only for choosing “lb” unit.

F1.2: Calibration mode selecting, with 3 options

F1.2=1 fixed point calibrating and selecting internal preset Max. capacity.
F1.2=2 arbitrary point calibrating and selecting internal preset Max. capacity.
F1.2=3 arbitrary point calibrating and selecting Max. capacity.

F1.3. Baud rate selecting, with total 5 options

F1.3=1 B=600

F1.3=4 B=4800

F1.3=2 B=1200

F1.3=5 B=9600

F1.3=3 B=2400

F.1.4 Auto shut-off function, with 3 options.

F1.4=0 auto shut-off function off
F1.4=3 auto shut-off in 3 minutes after operation stopped
F1.4=5 auto shut-off in 5 minutes after operation stopped

When the version is less than REV2.0, you can only choose F1.2=3

F1.5 Serial output mode, with 2 options

F1.5=0 printing output (printer model: TM-U295)
F1.5=1 serial output.

F1.6.Selecting setup value from F1.1 to F1.5, with 2 options.

F1.6 selection of setup value of the users
F1.6 selection of default value, refer to the following table

F1.1

1

F1.2

3

F1.3

2

F1.4

1

F1.5

1

*Notice: After the option of F1.6 is finished and if you press       (ENTER) to confirm, at this time the 
indicator will display                  again to enter next main directory.
When pressing          , you can re-select main directories. When pressing     (EXIT), you will exit from the 
main directory.

16.2.2 Subdirectories and contend about F2.

F2.1 Turn-on zero range selecting, with 4 options

F2.1=0 auto turn-on zero function off.
F2.1=5 turn-on zero range of 5 % F·S
F2.1=10 turn-on zero range of 10 % F·S
F2.1=20 turn-on zero range of 20 % F·S

F2.2 Auto zero tracking range selecting, with 5 options

F2.2=0.0 no zero tracking.
F2.2=0.2 auto zero tracking of 0.2e
F2.2=0.5 auto zero tracking of 0.5e
F2.2=1.0 auto zero tracking of 1.0e
F2.2=2.0 auto zero tracking of 2.0e
F2.2=3.0 auto zero tracking of 3.0e

ENTER

T

UNITS

C

EXIT

BL

USER’S MANUAL

CWP. Bench scale

Содержание CWP

Страница 1: ...CWP Bench scale USER S MANUAL...

Страница 2: ...2 Backlight selecting 13 Auto rectifying 14 Storage battery maintaining 15 Use guide 16 Data setting and calibrating 3 3 4 6 7 7 9 9 9 9 11 12 12 12 13 13 CONTENTS USER S MANUAL CWP Bench scale Discla...

Страница 3: ...gnal input range 0mV 8mV 1 2 Zero point temperature drift 0 15 V C 1 3 Sensitivity temperature drift 10 ppm C 1 4 A D conversion resolution ration 500000 1 5 Display resolution ration 30000 1 6 A D co...

Страница 4: ...ustable support Load cell input 7 core RS 232 Interface 5 core Power supply adaptor Battery switch Seal ring assembly PCB Indicator enclosure Indicator rear cover Storage battery Battery box cover Fig...

Страница 5: ...gle cursor appears here See item 12 3 for details 7 CHARGE indicating symbol it is on when the battery is recharging 8 Auto Off indicating symbol When you switch on the auto shut off function the tria...

Страница 6: ...pressing this key and the cursor on the screen will change from G to N At this time if tou remove the goods from the scale platform the screen displays a negative value Press this key again the displa...

Страница 7: ...At this time if you press the selected falshing digit will change in 0 1 2 9 0 For example to input a group of digit 2345 Step 1 Press C the indicator display Note While inputing the digit first press...

Страница 8: ...oad mark bit D2 0 normality D2 1 overload D1 Positive and negative mark bit D1 0 positive number D1 1 negative number D0 Gross weight and net weight mark bit D0 0 gross weight D0 1 net weight State C...

Страница 9: ...ic weighing mode after power on 7 POWER ON OPERATION I O POWER You can convert between basic weighing and check weighing by pressing MODE key 8 TWO WEIGHING MODES SWITCHING MODE SET After power on the...

Страница 10: ...and low limit value in percentage mode 10 4 1 After the target weight setup is finished and the indicator displays and if the item 10 4 2 can be met i e the absolute value of the value difference betw...

Страница 11: ...splay between value difference display and normal display by pressing key and press once the display will be converted once It can reserve the shift mode unless the power supply is cut off 11 4 Three...

Страница 12: ...will display At this time place a test weight or substitute on scale platform Because the division value and Max capacity are known the decimal point place need not to be considered So at this time o...

Страница 13: ...horisation contact our sales agent in your area 15 7 If you need to re calibrate the indicator do it after the indicator is warm up for 30 minutes 15 USE GUIDE Forbid changing the data of the scale un...

Страница 14: ...s less than REV2 0 you can only choose F1 2 3 F1 5 Serial output mode with 2 options F1 5 0 printing output printer model TM U295 F1 5 1 serial output F1 6 Selecting setup value from F1 1 to F1 5 with...

Страница 15: ...ct Min display value via and then press ENTER to confirm ENTER T UNITS ENTER T If the version number is less than REV2 0 then the Max Capacity must be through digit keys The steps are as following 1 D...

Страница 16: ...t this moment you can load test weights or substitute on the platform and press ENTER the indicator will display and then carry through countdown After the countdown is finished the whole calibration...

Страница 17: ...main directory and subdirectory by Figure 12b Press to enter subdirectory and enter next main directory by confirming the last subdirectory T F1 F1 1 1 F1 2 1 F1 6 1 F2 F2 1 0 F2 F1 1 2 F2 1 0 F1 2 2...

Страница 18: ...ER T UNITS F3 F1 Inputting or selecting Max capacity Selecting decimal point Confirming zero positioning Arbitrary point loading Fixed point loading d 1 Select 1 2 or 5 by Count down SCL 09 F3 Self te...

Страница 19: ...19 USER S MANUAL CWP Bench scale...

Страница 20: ......

Отзывы: