14 Appendix
14.1 Combustion check on small heating systems
1. Use the procedure shown below to carry out the combustion check.
Fig.74
Small system combustion check
Combustion Check
Turn DHW knob to MAX
& open DHW taps to
create demand
Press button 5 times
until load value displayed
No
Open more DHW taps to
increase to maximum
load
Close all DHW taps
Yes
Start Chimney Sweep
mode - see section 7.
Measure & record
combustion
• If incorrect at
commissioning call Baxi
Customer Support
0344 871 1545
• If incorrect when
changing gas valve
adjust & re-check as
described in
Section 10
Measure & record combustion
• If incorrect at commissioning call Baxi Customer Support 0344 871 1545
• If incorrect when changing gas valve adjust & re-check
Stop chimney sweep mode by pressing
button for 3 seconds
Is load
reading
100?
Is load
reading
100?
Load reading
Yes
Start Chimney Sweep mode - see
Section 7 - and set to minimum load.
If changing gas valve adjust & re-check
as described in section 10.
Yes
No
PN-0000542
Can the
appliance be operated
on central heating for 10 mins
without reaching
maximum
temp?