8. Remove the flue elbow and insert the flue through the hole in the wall.
Fit the flue trims if required, and refit the elbow to the boiler adaptor,
ensuring that it is pushed fully in. Secure the elbow with the screws
supplied in the boiler fitting kit.
1
Flue elbow
2
Boiler adaptor
3
Telescopic flue
4
Flue trim
5
Securing screw
A
Apply the lubricant supplied for ease of assembly (do not use
any other type). Ensure flue is fully engaged into elbow.
B
Apply the lubricant supplied for ease of assembly (do not use
any other type). Ensure elbow is fully engaged into boiler
adaptor.
C
Peak to be uppermost
9. Draw the flue back through the wall and engage it in the elbow. It may
be necessary to lubricate to ease assembly of the elbow and flue.
10. Ensure that the terminal is positioned with the slots to the bottom.
Secure to the elbow with the screws supplied with the telescopic flue.
Important
It is essential that the flue terminal is fitted as shown to ensure
correct boiler operation and prevent water entering the flue.
11. Make good between the wall and air duct outside the building,
appropriate to the wall construction and fire rating.
12. If necessary fit a terminal guard.
Important
There must be no part of the air duct (white tube) visible outside
the property.
6.4
Electrical connections
See
Electrical supply, page 24 for details of the electrical supply.
Warning
Check that the total nominal consumption of the accessories
connected to the appliance is less than 1 amp. If it is higher, a
relay must be installed between the accessories and the electronic
board.
6.4.1
Panel removal to make electrical connection
Remove the plastic protective coating from the front of the boiler.
Unscrew the two screws retaining the electrical cover at the bottom of the
front panel and then remove the cover.
Fig.36
Attaching the flue
PN-0000465
1
2
3
4
4
5
A
B
C
6 Installation
42
7696317 - 1 - 21032018