![Baxi Combi 200 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/baxi/combi-200/combi-200_installation-and-service-manual_2711716068.webp)
Group
code
Specific
code
Description
Probable cause
Check/Reason
E:02
.21
Jumper 3 changed
Check position of jumper 3
Put jumper 3 to the off position
E:02
.47
Connection to external device
unsuccessful
Check wiring to external device
Check wiring
E:02
.48
Configuration to external device
unsuccessful
Check pairing to external
Pair the devices
E:04
.00
Gas Valve fault
Gas valve not detected
Check the wiring
Check resistance across gas
valve terminals
Replace gas valve if necessary
E:04
.01
Flow temperature sensor short-
circuited
Sensor not or badly connected
Bad connection
Sensor fault
Check the wiring
Check that the sensors are oper
ating correctly
Check that the sensor has been
correctly fitted
Replace the sensor if necessary
E:04
.02
Flow temperature sensor open-
circuited
Sensor not or badly connected
Bad connection
Sensor fault
Check the wiring
Check that the sensors are oper
ating correctly
Check that the sensor has been
correctly fitted
Replace the sensor if necessary
E:04
.03
Critical flow temperature
reached
Non-existent or insufficient circu
lation
Check circulation
E:04
.04
Flue temperature sensor short-
circuited
Sensor not or badly connected
Bad connection
Sensor fault
Check the wiring
Check the sensors are operating
correctly
Check the sensor has been cor
rectly fitted
Replace the sensor if necessary
E:04
.05
Flue temperature sensor open-
circuited
Sensor not or badly connected
Bad connection
Sensor fault
Check the wiring
Check the sensors are operating
correctly
Check the sensor has been cor
rectly fitted
Replace the sensor if necessary
E:04
.06
Critical flue gas temperature
reached
No circulation
Sensor fault
Vent the air in the heating sys
tem
Check the water pressure
Check the wiring
Check the circulation (direction,
pump, valves)
Check the cleanliness of the
heat exchanger
Check that the sensors are oper
ating correctly
Check that the sensor has been
correctly fitted
Replace the sensor if necessary
E:04
.08
Maximum safe temperature
reached (Safety thermostat
open-circuited)
No circulation
Sensor not or badly connected
Bad connection
Sensor fault
Vent the air in the heating sys
tem
Check the water pressure
Check the wiring
Check the circulation (direction,
pump, valves)
Check the cleanliness of the
heat exchanger
Check that the sensors are oper
ating correctly
Check that the sensor has been
correctly fitted
Replace the sensor if necessary