4
1.0
Introduction - Page 4
NOTE: A red indicator (Fig. 1) shows when the electric
power is ON but the fan is not running.
The fire incorporates a fan so that it can be installed in a
room without a flue. The fan removes the products of
combustion horizontally through a flue duct which exits
at the rear of the appliance.
1.1 Description
1. The Baxi Belmont 2 and Wentworth Classic Fan Flue are
live fuel effect inset gas fires designed to be used on Natural
Gas only at a setting pressure of 20 mbar.
2. The appliance is designed to give a maximum heat output
of 3.0 kW (10,236 Btu/h).
3. The fire is controlled by a knob which is positioned behind
the controls access door on the fender assembly (Fig. 1).
The knob has four positions:
Position
Off
Position
Ignition
Position
Minimum Output
Position
Maximum Output
4. The fan is controlled by the two rocker switches adjacent
to the control knob (Fig. 1).
5. A special feature of the Baxi Belmont 2 and Wentworth
Classic is the direct acting oxygen depletion system. This
system will shut down the appliance if there is inadequate
ventilation and the flue is not clearing the products of
combustion.
Under no circumstances shall this device be
adjusted, bypassed or put out of action.
The device must
be regularly serviced and strictly in accordance with these
instructions.
1.2 Important Information
This product contains Refractory Ceramic Fibres (R.C.F.)
which are man-made vitreous silicate fibres. Excessive
exposure to these materials may cause temporary irritation
to eyes, skin and respiratory tract. Care must be taken when
handling these articles to ensure the release of dust or fibres
is kept to a minimum. To ensure that the release of fibres
from these articles is kept to a minimum, during installation
and servicing it is recommended that a H.E.P.A. filtered
vacuum is used to remove any dust, soot or other debris
accumulated in and around the appliance. This should be
performed before and after working on the installation, It is
recommended that any replaced item(s) are not broken up
but sealed within heavy duty polythene bags and clearly
labelled R.C.F. waste”. This is not classified as “hazardous
waste” and may be disposed of a tipping site licensed for the
disposal of industrial waste. Protective clothing is not
required when handling these articles but it is recommended
that gloves are worn and the normal hygiene rules of not
smoking, eating or drinking in the work area are followed and
always wash hands before eating or drinking.