6
2.0
Technical Data - Page 6
Belmont 2 Fan Flue
Wentworth Classic Fan Flue
Category of Appliance
2H
The fire is set for Gas Type G20 at 20mbar.
Heat Input
(net)
kW
Btu/h
High
6.16
21,018
Min
2.4
8,200
Heat Output
kW
Btu/h
High
3.0
10,236
Inlet Setting Pressure
mbar
in wg
Cold
20 ± 1.0
8 ± 0.4
Gas Connection
8mm OD tube, rigid or
semi rigid and 8mm
compression fitting at
appliance inlet
Terminal Position with Minimum Distance (Fiq. 17)
(mm)
Controls &
Rotary gas tap with direct
Safety system
burner ignition, flame
A
Directly below an openable window or other opening,
failure device, direct
e.g. an air brick.
300
acting oxygen depletion
B
Below gutters, soil pipes or drain pipes.
75
system and a fan on/off
C
Below eaves.
200
switch with fan off
D
Below balconies or car port roof.
200
indication
E
From vertical drain pipes and soil pipes.
75
F
From internal or external corners.
300
Gas Rate
0.65 m
3
/h
G
Above ground, roof or balcony level.
300
(after 10 mins)
(23.0 ft
3
/h)
H
From a surface facing a terminal.
600
I
From a terminal facing a terminal.
1200
Lifting Weight
18.3 kg (40 Ibs)
J
Vertically from a terminal on the same wall.
1500
K
Horizontally from a terminal on the same wall.
300
Injector
Cat 127/440
L
For an opening in a car port (e.g. door, window) into
a dwelling.
1200
Trim
Height 601 mm
Dimensions
Width
512 mm
Depth
125 mm
(from the wall)
Electricity
230 Volts
Supply
Fan supply