The commissioning details for the Baxi Ambiflo
™
Heat Pump are given in the separate booklet supplied
with this unit. Please see page 4 of these installation instructions for details of the commissioning service
offered by Baxi.
The system should be fully power flushed prior to filling and commissioning to maintain the product
warranty.
After filling the unit and pressurising it, check that the system pressure is maintained and no air locks or
leaks are apparent.
NOTE: The guarantee is subject to the unit being installled and commissioned in
accordance with the manufacturer's instructions.
Page 21
6.0 Technical Data
6.1 Ambiflo
™
75, 90, 105
HEATING
Heating Capacity (Gross)
75 model
kW
7.25
90 model
kW
9.24
105 model
kW
10.65
Nominal Power Consumption (Net)
75 model
kW
2.65
90 model
kW
3.19
105 model
kW
3.62
Performance Factor (COP)