1.4 Guarding
1. This unit contains electrical components and moving parts.
These components, and the surrounding system pipework, operate at high temperatures. Where young
children or animals are concerned, Baxi recommend a barrier or guard to avoid tampering. The guard
must be of a suitable design and not restrict the air flow through the unit. A risk assessment MUST be
carried out prior to installing the unit.
NOTE: A guard is available from Baxi as an accessory if required.
Part number 5134518
–
Guard Ambiflo
™
75 & 90.
Part number 5134519
–
Guard Ambiflo
™
105.
2. See Fig. 16 for the orientation of the guard and please refer to the separate instructions for fixing details
and clearances required.
Page 7
2.0 General Layout
2.1 Layout
The Baxi Ambiflo
™
air source heat pump unit includes an integral circulation pump (3 speed to optimise
comfort and efficiency), small expansion vessel, pressure gauge and pressure relief valve. An additional
expansion vessel may be required.
1. Sound-proofed hermetic compressor.
2. Plate water heat exchanger.
3. "Plate-Fin" air heat exchanger.
4. Fan.
5. Fan protection grille.
6. Electrical box.
7. Baxi Ambiflo
™
Heat Pump control unit.
8. Circulating pump.
9. Expansion tank.
10. Safety valve.
11. Pressure gauge.