Baxi Ambiflo 105
Fig. 23
Water Volume in System
Minimum water volume (**) before Buffer required
models
(75)
(90)
(105)
litres
50
70
90
(**) If the water volume of the system is below the minimum, a buffer tank must be installed
Part No 5131503 (35 litres)
Part No 5131537 (100 litres)
If the water volume of the system is above 90 litres an additional expansion vessel is required. See Fig.
24.
Expansion Vessel Sizing Chart (mono-valent system) for 50°c return