PRODUCT SAFETY

•

Installation  and  servicing  is  only  to  be  carried  out  by  suitably  qualified  and

experienced personnel to local or national wiring standards.

•

Good engineering practice must be carried out at all times and all servicing and

repairs carried out indoors.

•

Hyper-D series cameras are to be powered with a class 2 power supply.

•

Under no circumstances must the power consumption of the Auto Iris connector

exceed 50 mA or the Direct Drive connector exceed 25 mA.

•

The Hyper-D range is designed for use in general purpose CCTV applications

and has no other purpose.

•

Only operate your camera between the temperatures of -10

O

C and +50

O

C.

In order to avoid damaging the camera note the following points.
1) Before  fitting  the  lens  make  sure  that  its  back  will  not  touch  the  sensor  or

associated components when screwed fully home.

2) Do  not  touch  the  image-surface  of  the  sensor.    If  the  sensor  is  accidentally

touched, only clean it using ethyl alcohol.

3) Do not expose the sensor to direct sunlight as this may impair the performance

of the camera.

4) For outdoor use, an appropriate protective housing conforming to IP65 or UL50

or better must be used.

MANUFACTURER’S DECLARATION OF CONFORMANCE

The manufacturer declares that the equipment supplied with this manual is compliant with

the essential protection requirements of the EMC directive 89/336/EEC and the CE Marking

Directive  93/68  EEC.  The  equipment  conforms  to  the  requirements  of  standards

BSEN61000-6-3:2001 for Emissions, BSEN50130-4:1996 (with amendments A1 and A2)

for Immunity and BSEN60950:2002 for Electrical Equipment Safety.

ELECTROMAGNETIC COMPATIBILITY (EMC)

This is a class A product. In a domestic environment this product may cause radio

interference in which case the user may be required to take adequate measures.

This product is intended solely for use in general CCTV applications.
The product must be installed and maintained in accordance with good installation practice

to enable the product to function as intended and to prevent problems. Refer to your agent

for installation guidance.

Содержание HYPER-D Series

Страница 1: ...HYPER D Series Cameras Installation Instructions Please read these instructions first ...

Страница 2: ...stallation Instructions 2 IMPORTANT The first few pages of these instructions contain important information on safety and product conformity Please read and ensure that you understand this information before continuing ...

Страница 3: ...r camera and have them available for its lifetime If you have any problems contact Baxall Limited FEATURES The Hyper D camera range has been designed to function with the minimum of set up The default settings of the camera should be able to cope with most applications The lens type DC Video or Manual is automatically detected by the camera and adjusted accordingly ...

Страница 4: ... touched only clean it using ethyl alcohol 3 Do not expose the sensor to direct sunlight as this may impair the performance of the camera 4 For outdoor use an appropriate protective housing conforming to IP65 or UL50 or better must be used MANUFACTURER S DECLARATION OF CONFORMANCE The manufacturer declares that the equipment supplied with this manual is compliant with the essential protection requ...

Страница 5: ...en POWER LED on the rear panel indicates when power is connected 1 Low voltage power supply terminals 2 Composite video output BNC 3 Power LED 4 Decrease parameter button 5 Menu down button 6 Increase parameter button 7 Menu up button 8 Enter button 9 DD Video Lens conector 10 Back focus adjustment screws 11 Video format selector switch 12 1 4 20 UNC mounting bush top and bottom ...

Страница 6: ...s is once again obtained If you pass the point of best focus repeat the procedure The last turn of the back focus adjustment screw must always be in a clockwise direction Do not over turn or force the back focus mechanism VIDEO FORMAT SELECTOR The video format switch is used to select the video format required LENS CONNECTIONS Connect the auto iris lens to the 4 pin iris drive connector located on...

Страница 7: ... shown below will be displayed on the monitor Navigating the Menu System Use the direction buttons to navigate the menu and to select parameters Exiting the Menu System The menu system can be exited by selecting SAVE AND EXIT with the up down menu buttons and then pressing the Enter button Any changes made while within the menu system will be saved The menu system will be automatically exited if a...

Страница 8: ...camera s performance at low light but improves image quality in bright conditions This is the preferred setting for well lit scenes MED This setting limits the system gain to 15dB This setting provides a good balance between low light performance and overall image quality DNR This setting has a maximum gain of 24dB DNR is a Dynamic Noise Reduction system that reduce AGC noise by means of a field i...

Страница 9: ...s setting limits the white balance range to 2800 6500K This provides a more accurate colour rendition WIDE This setting extends the white balance range to 2500 9500K FLUORESCENT ON Reduces colour rolling that may occur under some types of fluorescent lighting To be used with line lock synchronisation AC supply only OFF The default setting maximises dynamic range MODE NORMAL AGC MED WHITE BALANCE R...

Страница 10: ... 360 For adjusting vertical phase when synchronised to an AC supply Note Line lock synchronisation may cause some issues with on screen displays In these circumstances the camera should be set to internal synchronisation MOUNTING Mounting points 12 figure 1 are provided on the top and bottom of the camera and are used to mount the camera on a bracket or tripod Only use standard photographic 1 4 20...

Страница 11: ...chnology Image size 6 3mm diagonal type 1 3 Sensor array size 5 04mm H x 3 78mm V Pixel size 7mm x 7mm Picture elements total 742 H x 554 V effective 720 H x 540 V Power supply 12VDC 15 24VAC 15 Power consumption 5 W Weight 0 55 kg Operating temperature 10 to 50 C 14 to 122 F Operating humidity 20 to 80 RH non condensing Storage temperature 10 to 70 C 14 to 158 F Storage humidity 20 to 90 RH non c...

Страница 12: ...sue 1 01 04 Baxall Limited Stockport England Visit our Web site http www baxall com Baxall Limited reserve the right to make changes to the product and specification of the product without prior notice to the customer ...

Отзывы: