Troubleshooting the TransTrax
®
This section assumes that the machine in question has been inspected for loose, damaged or
missing parts, tape, belts, wiring, etc.
If the unit has a connector board located behind the customer speaker panel, remove the connecting
and audio wires from the connector board and hardwire together matching color to color.
NOTHING WORKS:
Check the circuit breaker on the bottom of the Teller Unit Standoff. Reset it by toggling it off and
back on. Nothing still works, check to insure that there is 110 VAC power coming into the
machine. If there is no AC Power, have an electrician restore power to the machine. If there is
power, check the fuse marked F1. If it is blown replace it with a 10A fast blow fuse. If the fuse
blows again, replace the control board. If nothing still works, please consult the factory.
POWER ON LED WON'T COME ON OR GO OFF:
Check the
LED
marked
PWR
while pressing the
POWER SWITCH
. The
PWR LED
should only
be on while the switch is depressed. If the
PWR LED
is on all the time, replace the
INSIDE
SWITCH
ASSEMBLY
. If the
PWR LED
does not come on, check the switch on the brake control
board to insure that it is in the normal position. If the
PWR LED
still will not come on replace the
INSIDE SWITCH ASSEMBLY
. If the
PWR LED
still does not come on replace the control board.
CARRIER WON'T RUN IN WHEN RECALL BUTTON IS DEPRESSED:
This presumes that the carrier will run out. Check the
LED
marked T-L, inside limit. It should not
be on. If it is, replace the
INSIDE STOP SWITCH
. If it is not, press the button marked recall.
When the recall button is depressed, the LED marked RCL, recall, should be on. If it does not
come on, replace the
INSIDE SWITCH ASSEMBLY
. If it does come on, replace the
CONTROL
BOARD
.
CARRIER WON'T RUN IN WHEN CUSTOMER START BUTTON IS DEPRESSED:
This presumes that the carrier will run out. Check the LED marked T-L, inside limit. It should not
be on. If it is, replace the
INSIDE STOP SWITCH
. If it is not, press the customer start button.
When the button is depressed, the LED marked RCL, recall, should be on. If it does not come on,
replace the
CUSTOMER START SWITCH
. If it does come on, replace the
CONTROL BOARD.
CARRIER WON'T RUN OUT WHEN THE CAR BUTTON IS DEPRESSED:
This presumes that the carrier will run in. Check the
LED
marked C-L, customer limit. It should
not be on. If it is, replace the
CAR STOP SWITCH
. If it is not, press the inside button marked
CAR
. When the button is depressed, the
LED
marked
SND
, send, should be on. If it does not
come on, replace the
INSIDE SWITCH ASSEMBLY
. If it does come on, replace the
CONTROL
BOARD
.
CARRIER WON'T RUN OUT WHEN THE TRUCK BUTTON IS DEPRESSED:
This presumes that the carrier will run in. Check the
LED
marked
TR-L
, truck limit. It should not
be on. If it is, replace the TRUCK STOP SWITCH. If it is not, press the inside button marked
TRUCK
. When the button is depressed, the
LED
marked
TRK
, truck send, should be on. If it
does not come on, replace the
INSIDE SWITCH ASSEMBLY
. If it does come on, replace the
CONTROL BOARD
.