TAM 00624
9
DS 100 – 200
03 / 2005
Three-phase synchronous motor, air-cooled
English
2.5 Transport, intermediate storage
Transport:
Suitable load suspension material must be used, e.g. belt webbing, loop belts etc. If
provided, the lifting lugs of the motor can be used for lifting.
The terminal boxes or motor connectors must not be used as shipping braces or lifting
lugs.
The regulations in the respective countries must be adhered to during transport. Lifting
devices, transport and load suspending devices must comply with the regulations.
The Baumüller electric motors of the
"DS...“
series weigh up to approx.
600 kg
. Precise details
relating to the weight of the respective decices can be found in the technical documantation that
comes with the product.
The motor shaft and the connection surfaces must be protected against
corrosion. The motor must be transported with motor shaft covering to prevent unnecessary
damage to the shaf
Air inlet and outlet openings must be covered to prevent any foreign matter ingress into the fan
during transport.
Intermediate storage:
If a motor is not to be commissioned immediately after delivery, it should be stored inside a building
in a dry, dust-free and low-vibration room (V
eff
= 0.2mm/s).
The electric motors can be stored for a maximun of two years at -30°C to +60°C. High storage
temperatures up to a max. of +85°C are permitted, but this can, however, lead to the ageing of the
gaskets. Direct exposure to incident solar radiation, UV light and ozone can also lead to an ageing
of the gaskets and must be avoided !
Please note that the warranty periods commence from the date of delivery. For this reason, we
recommend that storage periods be reduced to a minimum.
2.6 Installation conditions, cooling details
Surroundings:
The motor can be installed in roofed over rooms with dusty or damp ambient conditions and normal
climatic conditions. The motor must not be brought into contact with aggressive, corrosive, abrasive
or plastic-dissolving solutions. Dust filters with micro-filter mats must be interposed where air
containing dust particles is used as cooling air.
The warmed-up motor exhaust air – even of adjacent units – must not be taken in again.
Consultation with the motor manufacturer is essential in the case of outside installation.
Ambient conditions comp.
Chap. 2.4
and the technical documentation that comes with the product.
Information on required cooling quantities
The following cooling amounts are required to cool the DS motors:.
DS frame size
100 132 160 200
Min. air quantity
[m³/min]
≥
2.4
≥
5.8
≥
9.5
≥
16.5
Min pressure [Pa]
≥
180
≥
370
≥
640
≥
850