TAM 00624
8
DS 100 – 200
03 / 2005
Three-phase synchronous motor, air-cooled
English
Electrical connections (comp.
Appendix 1
)
Main connection
Terminal box
Control connection
Resolver - 12-pole connector
Fan / built-in fan motor
6-pin connector
(unit DA 100)
Fan / added-on standard motor
Terminal box, standard motor (unit DA 132 -280)
Brake (optional)
Separate connection
Thermal sensor
Connection in terminal box
Thermal motor protection (EN60034-11)
Thermal sensor KTY84 in stator winding
Winding insulation (EN 60034-1)
Insulation class F
Ambient temperature
0°C ... +40°C
Installation (EN 60034-1)
= 1.000 m a.m.s.l.
Storage
-30°C…+60°C (+ 85°C,
comp. Chap. 2.5
)
Bearing
Rolling-contact bearing with grease lubrication for life
Calculated bearing life
20.000h (tentative value)
Vibration severity (EN 60034-14)
Level N
Vibration-resistant to … (to EN 60068-2-6)
Radial 3g (20Hz to 55 Hz)
Axial 0.5g (20Hz to 55 Hz)
Holding brake
Option
Actual speed encoder
Standard:
2-pole
Resolver
For further technical values, please refer to the technical documentation that comes with the
product.
Attention!
If the electric motor supplied is not a standard version in accordance with the technical
documentation or if special arrangements were contractually agreed, the technical data may differ
to the values stated in these Commissioning and Maintenance Instructions. The supplementary
technical details are available on request.