Baumer TCR6 Скачать руководство пользователя страница 3

www.baumer.com 

The CombiTemp™ TCR6 can be mounted in more different ways. 

1. 

Sensor tube without connection  

 Baumer offers compression glands fitting Ø6 and Ø8 mm sensor diameter. 

 

 

 

 

 This type of mounting is normally used for mounting a sensor direct into a non-pressurized application. If pressurized, ensure that the 
connection is tightened correct, so no leakage occur.    

 

 

 

 

 

 
A duct channel mounting flange for 8 mm sensor is also available (type: ZPX1-002) 

 

 

 

 

 
All threaded connection can be mounted direct into the application without thermowell, however often a thermowell is required to enable the user 
to take out the sensor for e.g. calibration without opening the system. 
 
2. 

Sensor with male threaded process connection G 1/2 A  

 

This G 1/2 A connection can be mounted in a Baumer thermowell type ZPT4.   

 

The process connection available are R 1/2, G 1/2 A, G 3/4 A, M20×1,5  

 

 

 

 

or with hygienic ISO 2852 clamp DN 38 

3. 

Sensor with male threaded process connection G 3/4 A and G 1 A and sensors with G 1/2 or G 3/4 female thread 

 

For these connections a special thermowell can be supplied. 

 
Mount the gland/pocket into the application and install the sensor after the gland/pocket is fixed to the application. This will ensure that the cable is 
not twisted during mounting. 

Baumer recommend to use a thermal compound filled into the thermowell ensure best possible heat transfer between the pocket and the Com-
biTemp TCR6. 

Baumer offers a 6 gram bag Thermal compound, type ZPX1-001. 

 Mounting 

 

Electrical connection

 

Temperature transmitter 

Ceramic terminal block 

            Pt100 

2-w  4-w           3-w  2-w 

 

 

 

              

-      + 

 

          

4...20 mA

   

                       

Pt100

 

 2-w

      

3-w

 

           

4-w       2-w

 

White

   

White           

 

   

Red 

     

Red 

          Warning

 

Note: Check the maximum temperature for the cable used.

 

Ambient temperature with built in transmitter: -40...85°C 

Page 3 / 16 

Operating instructions: 11119033 08

 

English 

Operating instructions for temperature sensor 

TCR6

 

 Industrial temperature sensor  

Ambient temperature with ceramic block: -40...160°C 

Cable sensor insert 

Single element, 4-wire 

Single element, 2-wire 

Double element 

M12 plug version 

Transmitter: 

Pin 1 = 4...20 mA + 
Pin 3 = 4...20 mA - 

 

Ceramic block, 2-wire: 

Pin 1/2 = 1st wire 
Pin 3/4 = 2nd wire 

 

Ceramic block, 4-wire: 

Pin 1 = 1st wire 
Pin 2 = 2nd wire 
Pin 3 = 3rd wire 
Pin 4 = 4th wire 

Ceramic block, double element 

Pin 1 = Element 1, 1st wire 
Pin 2 = Element 1, 2nd wire 
Pin 3 = Element 2, 1st wire 
Pin 4 = Element 2, 2nd wire 

Содержание TCR6

Страница 1: ...r substantial damage of property The product must be operated by trained staff Correct and safe opera tion of this equipment is dependent on proper transport storage installa tion and operation All el...

Страница 2: ...m A R 1 2 ISO 7 1 M18 M20 ISO 261 14 NPT ANSI ASME B1 20 1 G 1 2 A G 3 4 A G 1 A nipple ISO 228 1 G 1 2 G 3 4 union ISO 228 1 Sensor tip Standard Fast response 4 20 mm DIN form B head Response time ti...

Страница 3: ...supplied Mount the gland pocket into the application and install the sensor after the gland pocket is fixed to the application This will ensure that the cable is not twisted during mounting Baumer rec...

Страница 4: ...imple apparatus no transmitter or display The CombiTemp TCR6 can be supplied for hazardous area Either as a Simple Apparatus with RDT output or with built in transmitter with 4 20 mA output A CombiTem...

Страница 5: ...sind m gliche Auswir kungen auf andere Ger te und das gesamte System zu pr fen ATEX Anwendungen Konfiguration G ltig f r FlexTop 2202 2211 2221 Das FlexProgrammer Konfigurationsger t darf in der gef...

Страница 6: ...SI ASME B1 20 1 G 1 2 A G 3 4 A G 1 A Druck schraube ISO 228 1 G 1 2 G 3 4 berwurfmutter ISO 228 1 Sensorspitze Standard Schnell ansprechend 4 20 mm DIN Form B Kopf Ansprechzeit Zeitkonstante 0 5 Sens...

Страница 7: ...chl sse ist ein spezielles Schutzrohr lieferbar Die Verschraubung Schutzh lse in der Anwendung montieren und anschlie end den Sensor installieren Dadurch wird sichergestellt dass sich das Kabel bei de...

Страница 8: ...riere U 28 VDC I 0 1A P 0 7 W Ex Daten f r FlexTop 2211 und 2221 Zulassung ATEX II 1G Ex ia IIC T5 T6 Spannungsversorgung 2211 6 5 30 VDC 2221 8 30 VDC Interne Induktivit t Li 15 H Interne Kapazit t C...

Страница 9: ...ement et sur le syst me de traitement Application configuration ATEX Valide pour le FlexTop 2202 2211 2221 L unit de configuration FlexProgrammer ne doit pas tre connect e au FlexTop dans la zone dang...

Страница 10: ...3 4 A G 1 A m le tournant ISO 228 1 G 1 2 G 3 4 femelle tour nant ISO 228 1 Pointe du capteur Standard Temps de r ponse 4 20 mm T te DIN forme B Temps de r ponse constante de temps 0 5 Diam tre de la...

Страница 11: ...raccords Installez le presse toupe doigt de gant sur l application puis installez le capteur une fois le presse toupe doigt de gant fix l application Cela pr viendra toute torsion du c ble pendant le...

Страница 12: ...ta pour FlexTop 2211 et 2221 Homologation ATEX II 1G Ex ia IIC T5 T6 Alimentation 2211 6 5 30 V DC 2221 8 30 V DC Inductance interne Li 15 H Capacitance interne Ci 5 nF Plage de temp rature T1 T5 40 T...

Страница 13: ...www baumer com Page 13 16 Operating instructions 11119033 08 Operating instructions for temperature sensor TCR6 Industrial temperature sensor...

Страница 14: ...www baumer com Page 14 16 Operating instructions 11119033 08 Operating instructions for temperature sensor TCR6 Industrial temperature sensor...

Страница 15: ...www baumer com Page 15 16 Operating instructions 11119033 08 Operating instructions for temperature sensor TCR6 Industrial temperature sensor...

Страница 16: ...www baumer com Page 16 16 Operating instructions 11119033 08 For further information please refer to www baumer com...

Отзывы: