www.baumer.com
Sensor element specifications (DIN/EN/IEC 60751)
Sensor element
Pt100
Accuracy (sensor element)
Class B ±(0,3 + 0,005×t)°C
- 1/3 B ±1/3 × (0,3 + 0,005×t)°C
- 1/6 B ±1/6 × (0,3 + 0,005×t)°C
Class A ±(0,15 + 0,002×t)°C
Single element
1 × Pt100
Double element
2 × Pt100
Connection
2-wire or 4-wire
Sensor element
Pt1000
Accuracy (sensor element)
Class B ±1/3 × (0,3 + 0,005×t)°C
Connection
2-wire
Material
Stainless steel, AISI 316L
Sensor tube diameter
Ø6, Ø8 or Ø10 mm
Sensor tube and
process connection
R 1/2 (½” BSPT)
G 1/2 A
G 1/2
G 1/2 A, G 3/4 A
G 3/4 A
G 3/4
M18 × 1,5
G 1 A
M20 × 1,5
½-14 NPT
76
71
M20
Connection
A
A/F
L
Without
18.5
Ø18
25...3.000
G 1/2 A, R 1/2
20.5
22.0
25...3.000
M18, M20
20.5
22.0
25...3.000
½-14 NPT
20,5
22.0
25...3.000
G 1/2 A nipple
40,0
27.0
25...3.000
G 3/4 A nipple
44,5
32.0
25...3.000
G 1 A nipple
47,5
36.0
25...3.000
G 1/2 union
51.0
27.0
25...3.000
G 3/4 union
51.0
32.0
25...3.000
Connection
Norm
G 1/2 A
ISO 228/1
DIN 3852 form A
R 1/2
ISO 7/1
M18, M20
ISO 261
½-14 NPT
ANSI/ASME
B1.20.1
G 1/2 A, G 3/4 A,
G 1 A nipple
ISO 228/1
G 1/2, G 3/4 union
ISO 228/1
Sensor tip
Standard Fast response
Ø4 × 20 mm
DIN form B
head
Response time (time constant)
0,5
Sensor
diameter
Sensor
tip
Insert
Liquid
0,4 m/sec
Air
3 m/sec
Air
0 m/sec
Ø6 mm
Fast
<1,5 sec <21,4 sec <135,6 sec
Standard
<6,1 sec <27,2 sec <137,8 sec
8 mm
Fast
<1,5 sec <33,6 sec <181,0 sec
Standard
<7,6 sec <47,7 sec <200,9 sec
Standard
Yes
<13,6 sec <51,1 sec <253,1 sec
10 mm
Fast
<1,5 sec <46,8 sec <238,9 sec
Standard
<11,1 sec <57,8 sec <270,6 sec
Standard
Yes
<28,1 sec <67,0 sec <271,1 sec
°C
100
80
60
40
20
1
2
3
1: Sensor without thermowell (Embedded sensor)
2: Sensor with thermowell, with thermal compound
3: Sensor with thermowell, without thermal compound
Note: When a thermowell is used, the time delay increases.
The delay is the time duration for the sensor to reflect the correct
temperature after a temperature change in the media.
0 1
2
3
4
5
6
7
8
9
10 Minutes
Page 2 / 16
Operating instructions: 11119033 08
English
Operating instructions for temperature sensor
TCR6
Industrial temperature sensor