Manual_OADM20x659_DE_EN.doc
43/48
Baumer
04.12.12
Frauenfeld, Switzerland
Sensor
t1
t2
OADM 20I6591
< 2 ms
1.5 ... 6 ms
OADM 20I6592
< 2.5 ms
1.5 ... 7.5 ms
OADM 20I6593
< 3.5 ms
1.5 ... 10.5 ms
t1 is the max. time after a high signal on the synch. input of S1 until the analog value will be held. This value
will be held as long the signal on the synch. input is high.
The min. time between the high signal of S1 and the low signal of S2 is t1, also. In this case, an optical
influence between the sensors is not possible.
t2 is the time until the analog signal is ready after a low signal on the synch. input of S2. This time depends
on the reflectivity of the object and if the reflectivity changes during the hold time.
Input circuit
27k
Ω
10k
Ω
sync in
low: 0 .. 2V
high: 12 .. 28V
3V3