Switch Counts
For each individual SSC a switching counter is implemented, which can be used as diagnosis data or also as
measurement value. The number of counts of each channel can also be mapped to the measurement data
channel MDC by adjusting the MDC source. Trigger of counter is on positive slope of related SSC.
Note:
Each power up, the switch counts are being reset/start from 0.
Parameter name
Short Description
Rights
Unit / Allowed
values
-
SSC1 Switch Counts
Reset
-
SSC4 Switch Counts
Reset
Command to set the counter value of SSCn to
zero.
Available for SSC1 and 4.
wo
32 Bit value
-
Switch Counts.SSC1
Resetable
-
Switch Counts.SSC4
Resetable
Number of switching operations.
Available for SSC1 and 4.
ro
32 Bit value
4.2.3
MDC Source
Selects which measuring value is mapped to the MDC channel and is then available via the process data-IN
path. When SSC1, SSC2 or SSC4 is selected the number of switches detected by the channel is shown.
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Selection.Source
Defines the measuring value which is
mapped to the MDC channel for
availability via the process data-IN
path.
ro
-
Intensity (Only O200.R)
-
Quality Value
-
Switch Counter SSC1
-
Switch Counter SSC4
4.2.4
MDC Descriptor
This parameter allows to read out the limits of the measuring range of the sensor and unit. When the sensor
detects values outside of this range, it will report an out of range value (32760).
Parameter name
Short Description
Rights
Unit / Allowed
values
MDC Descriptor.Unit
Code
Shows the unit of the selected MDC source
ro
MDC
Descriptor.Lower Limit
lower limit of the measuring range
ro
MDC
Descriptor.Upper Limit
upper limit of the measuring range
ro