NE230
www.baumer.com
43
Data memory
>10 years in EEPROM
Reset
Button, electric or automatic
Keylock
Yes, electric (keylock)
Outputs relay
Normally open or closed, programmable
Output holding time
0.01...99.99 s
Interfaces
RS232, RS422, RS485
Standard
Protection class II
DIN EN 61010-1
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
Programmable
Operating modes
parameters
Sensor logic, scaling factor
count mode. control inputs
Approval
UL approval / E63076
Technical data - mechanical design
Ambient temperature
0...+50 °C
Storage temperature
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals D-SUB-female
connector, 9-pin (interface)
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 50 face DIN 0470-1
Operation / keypad
Membrane with softkeys
Housing type
Surface mount housing
Dimensions W x H x L
70 x 89 x 58 mm
Installation depth
58 mm
Mounting
DIN rail housing EN 50022
Weight approx.
300 g
Materials
Housing: GFV Polycarbonat
Rear: PPO, Keypad: Polyester
Technical data - trigger level
Comparator inputs
Input circuit
Inputs
PNP- / NPN-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1 A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms